3.2 Static Electrical Characteristics
Table 3. Static Electrical Characteristics
Characteristics noted under conditions 6.0 V VPWR 20 V, 3.0 V VDD 5.5 V, - 40 C TA 125 C, GND = 0 V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25 °C under nominal conditions, unless
otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER INPUTS
Battery Supply Voltage Range
• Fully Operational
• Extended mode(8)
Battery Clamp Voltage(9)
VPWR Operating Supply Current
• Outputs commanded ON, HS[0:1] open, IN[0:1] > VIH
VPWR
6.0
4.0
V
20
28
VPWR(CLAMP)
41
47
53
V
IPWR(ON)
mA
6.5
20
VPWR Supply Current
IPWR(SBY)
• Outputs commanded OFF, OFF Open-load Detection Disabled, HS[0:1]
shorted to the ground with VDD = 5.5 V
WAKE > VIH or RSTB > VIH and IN[0:1] < VIL
mA
6.5
7.5
Sleep State Supply Current
VPWR = 12 V, RSTB = WAKE = CLOCK = IN[0:1] < VIL, HS[0 :1] shorted to
ground
IPWR(SLEEP)
• TA = 25 °C
• TA = 85 °C
A
1.0
5.0
30
VDD Supply Voltage
VDD Supply Current at VDD = 5.5 V
• No SPI Communication
• 8.0 MHz SPI Communication(10)
VDD(ON)
3.0
5.5
V
IDD(ON)
mA
1.6
2.2
5.0
VDD Sleep State Current at VDD = 5.5 V
IDD(SLEEP)
5.0
A
Overvoltage Shutdown Threshold
VPWR(OV)
28
32
36
V
Overvoltage Shutdown Hysteresis
Undervoltage Shutdown Threshold(11)
VPWR(OVHYS)
0.2
0.8
1.5
V
VPWR(UV)
3.3
3.9
4.3
V
VPWR and VDD Power on Reset Threshold
VSUPPLY(POR)
0.5
0.9
VPWR(UV)
Recovery Undervoltage Threshold
VPWR(UV)_UP
3.4
4.1
4.5
V
VDD Supply Failure Threshold (for VPWR > VPWR(UV))
VDD(FAIL)
2.2
2.5
2.8
V
Notes
8. In extended mode, the functionality is guaranteed but not the electrical parameters. From 4.0 to 6.0 V voltage range, the device is only
protected with the thermal shutdown detection.
9. Measured with the outputs open.
10. Typical value guaranteed per design.
11. Output will automatically recover with time limited auto-retry to instructed state when VPWR voltage is restored to normal as long as the
VPWR degradation level did not go below the undervoltage power-ON reset threshold. This applies to all internal device logic that is
supplied by VPWR and assumes that the external VDD supply is within specification.
Analog Integrated Circuit Device Data