datasheetbank_Logo
データシート検索エンジンとフリーデータシート

07XSC200 データシートの表示(PDF) - Freescale Semiconductor

部品番号
コンポーネント説明
一致するリスト
07XSC200
Freescale
Freescale Semiconductor Freescale
07XSC200 Datasheet PDF : 51 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Table 3. Static Electrical Characteristics (continued)
Characteristics noted under conditions 6.0 V VPWR 20 V, 3.0 V VDD 5.5 V, - 40 C TA 125 C, GND = 0 V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25 °C under nominal conditions, unless
otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
OUTPUTS HS0 TO HS1 (CONTINUED)
HS[0,1] Current Sense Ratio (CSR1) Accuracy
(6.0 V < VHS[0:1] < 20 V) with 28W bit = 0
25 and 125 C
• IHS[0:1] = 12.5 A
• IHS[0:1] = 75 A
-40 C
• IHS[0:1] = 12.5 A
• IHS[0:1] = 75 A
CSR1_0_ACC
%
-20
20
-17
17
-28
28
-25
25
HS[0,1] Current Recopy Accuracy with one calibration point
(6.0 V < VHS[0:1] < 20 V) with 28W bit = 0(17)
• IHS[0:1] = 12.5 A
CSR1_0_ACC
(CAL)
-5.0
%
5.0
HS[0,1] Current Sense Ratio (CSR1) Accuracy
(6.0V < VHS[0:1] < 20V) with 28W bit = 1
25 and 125 C
• IHS[0:1] = 12.5 A
• IHS[0:1] = 37.5 A
-40 C
• IHS[0:1] = 12.5 A
• IHS[0:1] = 75 A
CSR1_1_ACC
%
-20
20
-17
17
-28
28
-25
25
HS[0,1] Current Recopy Accuracy with one calibration point
(6.0 V < VHS[0:1] < 20 V) with 28W bit = 1(17)
• IHS[0:1] = 12.5 A
CSR1_1_ACC
(CAL)
-5.0
%
5.0
Current Sense Clamp Voltage
• CSNS Open; IHS[0:1] = 5.0 A with CSR0 ratio
OFF OpenLoad Detection Source Current(18)
OFF OpenLoad Fault Detection Voltage Threshold
ON OpenLoad Fault Detection Current Threshold
ON OpenLoad Fault Detection Current Threshold with LED
• VHS[0:1] = VPWR - 0.75 V
VCL(CSNS)
V
VDD+0.25
VDD+1.0
IOLD(OFF)
30
100
A
VOLD(THRES)
2.0
3.0
4.0
V
IOLD(ON)
80
330
660
mA
IOLD(ON_LED)
mA
2.5
5.0
10
Output Short to VPWR Detection Voltage Threshold
• Output programmed OFF
Output Negative Clamp Voltage
• 0.5 A < IHS[0:1] < 5.0 A, Output programmed OFF
VOSD(THRES)
V
VPWR-1.2 VPWR-0.8 VPWR-0.4
VCL
V
- 22
-16
Output Overtemperature Shutdown for 4.5 V < VPWR < 28 V
TSD
155
175
195
C
Notes
17. Based on statistical analysis. It is not production tested.
18. Output OFF OpenLoad Detection Current is the current required to flow through the load for the purpose of detecting the existence of an
open-load condition when the specific output is commanded OFF. Pull-up current is measured for VHS = VOLD(THRES)
07XSC200
10
Analog Integrated Circuit Device Data
Freescale Semiconductor

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]