ELECTRICAL CHARACTERISTICS
DYNAMIC ELECTRICAL CHARACTERISTICS
Table 4. Dynamic Electrical Characteristics
Characteristics noted under conditions 3.0V VCC 5.5V, 7.0V VBAT 20V, - 40°C TA 125°C, GND = 0V, unless
otherwise noted. Typical values noted reflect the approximate parameter means at TA = 25°C under nominal conditions, unless
otherwise noted.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER OUTPUTS TIMING (OUT1 TO OUT5) (CONTINUED)
Driver Output Matching Time (t DLY(ON) - t DLY(OFF)) @ Output = 50% VBAT with Δ t RF
VBAT = 14 V, f PWM = 240 Hz, δPWM = 50%, @ 25 °C
SR bit = 0: IOUT = 2.8 A for OUT1 and OUT5 and IOUT = 5.5 A for OUT2/3/4
SR bit = 1: IOUT = 0.7 A for OUT1 and OUT5 and IOUT = 1.4 A for OUT2/3/4
- 30
- 15
PWM MODULE
μs
30
15
Nominal PWM Frequency Range(40)
f PWM
30.0
400
Hz
Clock Input Frequency Range
f CLK
7.68
51.2
kHz
Output PWM Duty Cycle maximum range for 11 V < VBAT < 18 V(40), (41)
PWM_MAX
4.0
96
%
Output PWM Duty Cycle linear range for 11 V < VBAT < 18 V(42)
PWM_LIN
5.5
96
%
Output PWM Duty Cycle range for full diagnostic for 11 V < VBAT < 18 V(43) PWM_DIAG
%
200 Hz Output PWM frequency
5.5
96
400 Hz Output PWM frequency
11
90
Notes
40. Not production tested.
41. The PWM ratio is measured at VOUT = 50% of VBAT in nominal range of PWM frequency. It is possible to put the device fully on (PWM
duty cycle = 100%) and fully off (PWM duty cycle = 0%). Between 4%-96%, OCHI1,2, OCLO and open load are available in ON state.
See Figure 6, Output Slew Rate and Time Delays.
42. Linear range is defined by output duty cycle to SPI duty cycle configuration +/-1 LSB. For values outside linear duty cycle range, a
calibration curve is available.
43. Full diagnostic corresponds to the availability of the following features: output current sensing, output status and open load detection. Not
production tested.
10XS353
14
Analog Integrated Circuit Device Data
Freescale Semiconductor

Share Link: 