datasheetbank_Logo
データシート検索エンジンとフリーデータシート

CDB6403 データシートの表示(PDF) - Cirrus Logic

部品番号
コンポーネント説明
一致するリスト
CDB6403
Cirrus-Logic
Cirrus Logic Cirrus-Logic
CDB6403 Datasheet PDF : 54 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
CS6403
Register SSI_CR0 (cont.)
BIT
GBC1
GBC0-
NAME
Graded-Beta Count
VALUE
FUNCTION
Graded-Beta Count - These bits control the rate at
which the update gain decays in the AEC as the
adaptive-filter taps are updated in a particular
sample time. For each setting below, some
number of taps are processed, after which the
update gain is divided by two. The possible
settings are given below:
Taps Processed
Equivalent path-decay rate
AECB1
AECB0
AEC Beta
00
512
01
64
10 R
128
11
256
0 dB/ms
0.75 dB/ms
0.38 dB/ms
0.19 dB/ms
These bits scale the adaptive filter update gain that
is present at the start of each sample time.
Update Gain
00
0.25
01
0.5
10 R
1.0
11
2.0
"R" indicates value after Reset
Recommended settings for D3-D0:
0001
0111
1010
1100
--No graded beta
--"dead" room/car;
0.75 dB/ms path decay
--medium room; (default)
0.28 dB/ms path decay
--large (or "live") room;
0.19 dB/ms decay
20