11. Reliability test results
Reliability Test Items
Test
cate-
gories
Test items
1 Terminal Strength
(Pull test)
2 Mounting Strength
Test methods and conditions
Pull force
Test time
Screw torque
Test time
: 20N
: 10±1 sec.
: 2.5 ~ 3.5 N・m (M5)
: 10±1 sec.
3 Vibration
4 Shock
1 High Temperature
Storage
2 Low Temperature
Storage
3 Temperature
Humidity
Storage
4 Unsaturated
Pressure Cooker
5 Temperature
Cycle
Range of frequency : 10 ~ 500Hz
Sweeping time
: 15 min.
Acceleration
: 100m/s2
Sweeping direction : Each X,Y,Z axis
Test time
: 6 hr. (2hr./direction)
Maximum acceleration : 5000m/s2
Pulse width
: 1.0msec.
Direction
: Each X,Y,Z axis
Test time
: 3 times/direction
Storage temp.
: 125±5 ℃
Test duration
: 1000hr.
Storage temp.
: -40±5 ℃
Test duration
: 1000hr.
Storage temp.
: 85±2 ℃
Relative humidity
: 85±5%
Test duration
: 1000hr.
Test temp.
: 120±2 ℃
Atmospheric pressure : 1.7 × 105 Pa
Test humidity
: 85±5%
Test duration
: 96hr.
Test temp.
: Low temp. -40±5 ℃
High temp. 125 ±5 ℃
6 Thermal Shock
Dwell time
Number of cycles
RT 5 ~ 35 ℃
: High ~ RT ~ Low ~ RT
1hr. 0.5hr. 1hr. 0.5hr.
: 100 cycles
Test temp.
+0
: High temp. 100 -5 ℃
+5
Low temp. 0 -0 ℃
Used liquid : W ater with ice and boiling water
Dipping time
: 5 min. par each temp.
Transfer time
: 10 sec.
Number of cycles
: 10 cycles
Reference
norms
EIAJ ED-4701
(Aug.-2001 edition)
Number
of
sample
Accept-
ance
number
Test Method 401
5
(0:1)
MethodⅠ
Test Method 402
5
(0:1)
m ethodⅡ
Test Method 403
5
(0:1)
Reference 1
Condition code B
Test Method 404
5
(0:1)
Condition code B
Test Method 201
5
(0:1)
Test Method 202
5
(0:1)
Test Method 103
5
(0:1)
Test code C
Test Method 103
5
(0:1)
Test code E
Test Method 105
5
(0:1)
Test Method 307
5
(0:1)
method Ⅰ
Condition code A
MS5F 5617
a
6
13
H04-004-03a