datasheetbank_Logo
データシート検索エンジンとフリーデータシート

MAX9546 データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
一致するリスト
MAX9546
MaximIC
Maxim Integrated MaximIC
MAX9546 Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MAX9546/MAX9547
Differential Video Interface Chipset
Absolute Maximum Ratings
(Voltages are referenced GND.)
VCC to GND........................................................ -0.3V to +11V
IN and FAULT (MAX9546)....................... -0.3V to (VCC + 0.3V)
OUT+, OUT- (MAX9546) (Note 1).............................-2V to +16V
FAULT Short-Circuit Duration to
VCC or GND (MAX9546)........................................Continuous
IN+, IN- (MAX9547) (Note 1)....................................-2V to +16V
IOUT, LOS, ZT+, ZT- (MAX9547).............. -0.3V to (VCC + 0.3V)
Differential Input Voltage (|VIN+ - VIN-|) (MAX9547)..............+5V
IOUT, LOS Short-Circuit Duration to
VCC or GND (MAX9547)........................................Continuous
Continuous Power Dissipation (TA = +70°C)
8-Pin SO-EP (derate 24.4mW/°C above +70°C).....1951.2mW
θJC (Note 2)....................................................................7.0°C/W
θJA.................................................................................41.0°C/W
Operating Temperature Range............................ -40°C to +85°C
Junction Temperature...................................................... +150°C
Storage Temperature Range............................. -65°C to +150°C
Lead Temperature (soldering, 10s).................................. +300°C
Note 1: The Absolute Maximum Ratings of OUT+/OUT- for the MAX9546 and IN+/IN- for the MAX9547 are based on a single-fault
condition, i.e. only one output of MAX9546 (or both outputs together) is shorted to the battery, VCC or GND. The devices will
not survive a double-fault condition, i.e. OUT+ and OUT- shorted to different supplies.
Note 2: Package thermal resistances were obtained using the method described in JEDEC specification JESD51-7, using a four-layer
board. For detailed information on package thermal considerations, refer to www.maximintegrated.com/thermal-tutorial.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
DC Electrical Characteristics–MAX9546
(VCC = +8.5V, RL = 220Ω between OUT+ and OUT-, TA = -40°C to +85°C. Typical values are at TA = +25°C, unless otherwise noted.)
(Note 3)
PARAMETER
Supply Voltage Range
Quiescent Supply Current
Voltage Gain
Input-Voltage Swing
Input Clamp Voltage
Input Clamp Current
Input Resistance
Output Common-Mode Voltage
Output Impedance
Output Fault Current
Power-Supply Rejection Ratio
FAULT Output Logic Level
FAULT Output Leakage Current
SYMBOL
VCC
ICC
AV
VIN
VCLMP
ICLMP
RIN
VCOM
ROUT
IF(OUT)
PSRR
CONDITIONS
Guaranteed by PSRR
No load
VIN = 1.2VP-P (Note 4)
Guaranteed by AV
(Note 5)
(Note 5)
(Notes 5, 6)
OUT+ and/or OUT- to +16V
OUT+ and/or OUT- to + (VCC - 2V)
OUT+ and/or OUT- to +2V
OUT+ and/or OUT- to -2V
OUT+ and/or OUT- to +16V, VCC
unconnected
OUT+ or OUT- to -2V, VCC unconnected
VCC from 7.5V to Differential mode
10V (Note 7)
Common mode
VOL, ISINK = 1.6mA (Note 8)
MIN TYP MAX UNITS
7.5
8.5 10.0
V
64
112
mA
1.8
2
2.2
V/V
1.2
3.46
VP-P
V
7
13
µA
500
kΩ
3.0 3.25 3.4
V
0.1
9
2
4
7
mA
6
24
45
62
dB
46
52
0.4
V
0.01
µA