datasheetbank_Logo
データシート検索エンジンとフリーデータシート

AD7824 データシートの表示(PDF) - Analog Devices

部品番号
コンポーネント説明
一致するリスト
AD7824 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
AD7824/AD7828
MICROPROCESSOR INTERFACING
The AD7824/AD7828 is designed to interface to microprocessors
as Read Only Memory (ROM). Analog channel selection, con-
version start, and data read operations are controlled by CS, RD,
and the channel address inputs. These signals are common to
all memory peripheral devices.
Z80 MICROPROCESSOR
Figure 16 shows a typical AD7824/AD7828–Z80 interface. The
AD7824/AD7828 is operating in Mode 0. Assume the ADC is
assigned a memory block starting at address C000. The follow-
ing LOAD instruction to any of the addresses listed in Table II
will start a conversion of the selected channel and read the
conversion result.
LD B, (C000)
At the beginning of the instruction cycle when the ADC
address is selected, RDY asserts the WAIT input so that the
Z80 is forced into a WAIT state. At the end of conversion,
RDY returns high and the conversion result is placed in the B
register of the microprocessor.
A15
ADDRESS BUS
A0
MREQ
Z80
WAIT
RD
D7
D0
EN
ADDRESS
DECODE
5V
5k
DATA BUS
A2
A1
A0
A0 A1 A2**
CS AD7824*
AD7828*
RDY
RD
DB7
DB0
*LINEAR CIRCUITRY OMITTED FOR CLARITY.
**FOR THE AD7828 ONLY
Figure 16. AD7824/AD7828–Z80 lnterface
Table II. Address Channel Selection
Address
C000
C001
C002
C003
C004
C005
C006
C007
AD7824
Channel
1
2
3
4
AD7828
Channel
1
2
3
4
5
6
7
8
MC68000 MICROPROCESSOR
Figure 17 shows an MC68000 interface. The AD7824/AD7828
is operating in Mode 0. Assume the ADC is again assigned a
memory block starting at address C000. A MOVE instruction
to any of the addresses in Table II starts a conversion and reads
the conversion result.
MOVE × B $C000, D0
Once conversion has begun, the MC68000 inserts WAIT states
until INT goes low, asserting DTACK at the end of conversion.
The microprocessor then places the conversion results into the
D0 register.
A23
A1
AS
R/W
MC68000
DTACK
D7
D0
ADDRESS BUS
A2
A1
A0
EN ADDRESS
DECODE
CLR
7474
D
Q CK
5V
5k
DATA BUS
A0 A1 A2**
CS
RD
AD7824*
AD7828*
RDY
DB7
DB0
*LINEAR CIRCUITRY OMITTED FOR CLARITY.
**FOR THE AD7828 ONLY
Figure 17. AD7824/AD7828–MC68000 Interface
TMS32010 MICROCOMPUTER
A TMS32010 interface is shown in Figure 18. The AD7824/
AD7828 is operating in Mode 1 (i.e., no µP WAIT states). The
ADC is mapped at a port address. The following I/O instruction
starts a conversion and reads the previous conversion result into
the accumulator.
IN, A PA (PA = PORT ADDRESS)
The port address (000 to 111) selects the analog channel to be
converted. When conversion is complete, a second I/O instruc-
tion (IN, A PA) reads the up-to-date data into the accumulator
and starts another conversion. A delay of 2.5 µs must be allowed
between conversions.
PA2
PA1
PA0
TMS32010
MEN
DEN
D7
D0
DATA BUS
A2**
A1
A0 AD7824*
AD7828*
CS
RD
DB7
DB0
*LINEAR CIRCUITRY OMITTED FOR CLARITY.
**FOR THE AD7828 ONLY
Figure 18. AD7824/AD7828–TMS32010 Interface
–10–
REV. F

Share Link: 