s INTERNAL SYSTEM DESCRIPTION
The NJU3101 is a C-MOS 4-Bit Single Chip Tiny Controller consisted of Original CPU Core, Selectable
Input-Output(I/O) Ports(MAX. 10 lines), Program ROM(512 bytes), Data RAM(16 nibbles), and Oscillator
Circuit which can select a type from four oscillators types(i.e. Ceramic or X'tal or CR oscillation or External
clock operation).
The CPU block in the NJU3101 is consisted of ALU(Arithmetic Logic Unit) executing the binary adding,
subtracting or logical calculating, AC(Accumulator), four Registers, STACK allowing the 8-level
subroutine-nesting, Program Counter indicating 512 addresses sequentially, and Timing generator.
The NJU3101 can be applied to the various markets because of the rich and efficient instruction set(58
instructions), wide operating voltage range(2.4V to 5.5V), low operating current, and STANDBY function
reducing the power supply current.
(1) INTERNAL REGISTER
Accumulator(AC)
Accumulator(AC) is structured by the 4-bit register. It holds a data or a result of calculation, and
executes the shift-operation(ROTATE) or the data transference between the other registers and Data
Memory(RAM).
Accumulator condition is unknown on the “RESET” operation.
X-register(X-reg)
X-register(X-reg) operates as the 4-bit register.
The X-reg condition is unknown on the “RESET” operation.
Y-register(Y-reg)
Y-register(Y-reg) operates as the 4-bit register or the RAM address pointer.
The Y-reg condition is unknown on the “RESET” operation.
X'-register(X'-reg)
X'-register(X'-reg) operates as the 4-bit register or a part of Program Memory(ROM) address pointer for
looking data in the ROM(TRM instruction) up function.
The X’-reg condition is unknown on the “RESET” operation.
Y'-register(Y'-reg)
Y'-register(Y'-reg) operates as the 4-bit register or the peripheral register number(PHYn) pointer.
The Y’-reg condition is unknown on the “RESET” operation.
(2) INTERNAL FLAG
RPC flag(RPC)
RPC flag(RPC) changes the instruction table. Several instructions perform either of the dual tasks in
accordance with the RPC flag condition. The RPC flag condition selects either of two couples of
registers which are X- and Y-reg, or X'- and Y'-reg. X- or Y-reg is selected when the RPC flag condition
is "0"(RPC=0). X'- or Y'-reg is selected when the RPC flag condition is "1"(RPC=1). The RPC flag
condition is set to "1"(RPC=1) by SRPC instruction, and is set to “0”(RPC=0) by RRPC instruction.
The RPC flag condition is set to “0” on the “RESET” operation.
CARRY flag(CY)
When the carry occurs after the adding calculation, the CARRY flag(CY) condition is set to "1"(CY=1),
and when no carry, the CY flag condition is set to "0"(CY=0). When the borrow occurs after the
subtracting calculation, the CY flag condition is set to "0"(CY=0), and when no borrow, the CY flag
condition is set to "1"(CY=1). The bit-operation instruction operates the bit data rotation on the CY flag
combined with Accumulator or the other register.
The CY flag condition is set to "1"(CY=1) by SEC instruction and is set to "0"(CY=0) by CLC instruction.
The CY flag condition is kept until the end of the next instruction executing cycle. The CY flag condition
is unknown on the “RESET” operation.