datasheetbank_Logo
データシート検索エンジンとフリーデータシート

ZR36067 データシートの表示(PDF) - Unspecified

部品番号
コンポーネント説明
一致するリスト
ZR36067
ETC
Unspecified ETC
ZR36067 Datasheet PDF : 48 Pages
First Prev 41 42 43 44 45 46 47 48
VSYNC
VStart’ VEnd’ VStart VEnd
floor or ceil (Ht/s)
AV PCI CONTROLLER
hcrop1
Wa
Ha/2
hcrop2
Total size of one input field
Active portion of one input field
The effective portion taken by the ZR36120 according to the
programmed parameters. (The effective portion can be the
entire active field or any partial sub-section of it).
Figure 17. Input Image Parameters
Calculating the Horizontal Parameters:
X and We denote two temporary variables:
X = ceil (VidWinWid*64/Wa)
We = floor (VidWinWid*64/X)
HorDcm = 64 - X
hcrop1 = 2*floor((Wa-We)/4)
hcrop2 = Wa - We - hcrop1
HStart and Hend are then calculated from hcrop1 and hcrop2.
In the example:
X = ceil(597*64/720) = 54
We = floor(597*64/54) = 707
HorDcm= 64 - 54 = 10
hcrop1 = 2*floor((720-707)/4) = 6
hcrop2 = 720-707 - 6 = 7
HStart = HStart’ + hcrop1 = 122 + 6 = 128
HEnd = HEnd’ - hcrop2 = 841 - 7 = 834
(834 - 128 + 1 = 707)
The ZR36067 will actually sample-in 707 pixels from every line.
The first 6 and the last 7 active pixels will be cut out.
Calculating the Vertical Parameters
(Regardless of DispMod!)
Y and He denote two temporary variables:
Y = ceil (VidWinHt*64*2/Ha)
He = floor (VidWinHt*64/Y)
VerDcm = 64 - Y
vcrop1 = floor((Ha/2 - He)/2)
vcrop2 = Ha/2 - He - vcrop1
VStart and VEnd are then calculated from vcrop1 and vcrop2.
In the example:
Y = ceil(199*64*2/480) = 54
He = floor(199*64/54) = 235
VerDcm= 64 - 54 = 10
vcrop1 = floor(((480/2) - 235) / 2) = 2
vcrop2 = (480/2) - 235 - 2 = 3
VStart = VStart’ + vcrop1 = 10 + 2 = 12
VEnd = VEnd’ - vcrop2 = 249 - 3 = 246
(246 - 12 + 1 = 235)
The ZR36067 will actually sample-in 235 lines from every field.
The first 2 and the last 3 active lines of every field will be cut out.
47

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]