datasheetbank_Logo
データシート検索エンジンとフリーデータシート

PCA1461 データシートの表示(PDF) - NXP Semiconductors.

部品番号
コンポーネント説明
一致するリスト
PCA1461 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Philips Semiconductors
32 kHz watch circuits with adaptive motor
pulse
Product specification
PCA146x series
PINNING
SYMBOL
VSS
TEST
OSC IN
OSC OUT
VDD
M1
M2
RESET
PIN
DESCRIPTION
1 ground (0 V)
2 test output
3 oscillator input
4 oscillator output
5 supply voltage
6 motor 1 output
7 motor 2 output
8 reset input
VSS 1
8 RESET
TEST 2
7 M2
PCA146xT
OSC IN 3
6 M1
OSC OUT 4
5 VDD
MSA937
Fig.1 Pin configuration, PCA146xT, (PMFP8).
FUNCTIONAL DESCRIPTION AND TESTING
The motor output delivers pulses of six different stages
depending on the torque required to turn the motor
(Figs. 3 and 4). Every motor pulse is followed by a
detection phase which monitors the waveform of the
induced motor voltage. When a step is missed a correction
sequence will be started (Fig.2).
Motor pulses
The circuit produces motor pulses of six different stages
(stage 1 to 5, stage 8). Each stage has two independent
modes: silver-oxide and lithium. The voltage level of VDD
determines which mode is selected (see Section “Voltage
level detector”).
Stages 1 to 5 (both modes) are used in normal operation,
stage 8 occurs under the following conditions:
Correction pulse after a missing step (both modes)
End-of-life mode
If stage 5 is not enough to turn the motor (both modes).
In the silver-oxide mode, the ON state of the motor pulse
varies between 56.25% and 100% of the duty factor
tDF = 977 µs depending on the stage (Fig.3). It increases
in steps of 6.25% per stage.
In the lithium mode, the ON state of the motor pulse is
reduced by 18.75% of the duty factor tDF (Fig.4) to
compensate for the increase in the voltage level.
After a RESET the circuit always starts and continues with
stage 1, when all motor pulses have been executed.
A failure to execute all motor pulses results in the circuit
going into stage 2, this sequence will be repeated through
to stage 8.
When the motor pulses at stage 5 are not large enough to
turn the motor, stage 8 is implemented for a maximum of
8 minutes with no attempt to keep current consumption
low. After stage 8 has been executed the procedure is
repeated from RESET.
The circuit operates for 8 minutes at a fixed stage, if every
motor pulse is executed. The next 480 motor pulses are
then produced at the next lower stage unless a missing
step is detected. If a step is missed a correction sequence
is produced and for a maximum of 8 minutes the motor
pulses are increased by one stage.