Protocols
The TCP/IP Internet Protocol Suite, normally referred to as TCP/IP after the main standards, was developed for the DAR-
PA/NSF Internet. The TCP/IP protocols have proved so popular that they are used for many networks not connected
to the Internet.
The protocols, standards and policies of TCP/IP are published by the Network Information Center (NIC) and are known
as Requests For Comments (RFCs). The TCP/IP protocols used by the TCPlink box are designed to conform to RFC
1122 ‘‘Host Requirements – Communications’’.
The IMS B300 incorporates firmware, implementing the following protocol elements:
Linkops Connection Server
Provides access to named subsystems over TCP/IP to remote users.
TCP and UDP transport services
The TCP implementation provides a reliable connection oriented transport layer, designed to meet Internet stan-
dards RFC793 and RFC 1122. UDP provides a datagram service, implemented to RFC768 and RFC 1122.
IP Network Layer
This layer is designed to meet Internet standards RFC791 and RFC1122 for IP layer behaviour.
Address Resolution Protocol
The dynamic Ethernet address resolution protocol, designed to meet Internet standards RFC826 and RFC1122.
Ethernet Data Link Layer
The Ethernet interface in the device encapsulates IP layer datagrams within Ethernet packets. The packetisa-
tion used is as specified in Internet standard RFC894 (i.e. Ethernet V2 Packetisation). The Data Link Layer re-
quirements of RFC1122 are also met by this layer.
5
Performance
A raw TCP data-rate of several hundred kilobytes/second is supported. Some reduction in total data bandwidth may occur
due to the host server or when multiple IMS B300 links are operating concurrently.
6
Specification
Feature
Power dissipation
Operating temperature
Weight
Length
Height
Depth
Value
Unit
25
W
10-40
°C
7
kg
421
mm
95
mm
251
mm
Links and system services signals are buffered to levels compatible with EIA RS-422. Inputs will also receive TTL compat-
ible signals and one side of the outputs can be used to drive TTL compatible loads. The serial interface provides a func-
tional subset of an EIA RS232 DCE. The IMS B300 is powered from AC mains and is compatible with worldwide mains
supplies. The unit is shock and vibration resistant to a level consistent with office and air-freight standards.
6.1 Mains connection
The IMS B300 may be connected to either a 110V or 240V mains supply and will automatically switch to the supplied
level. A clean mains supply is required in one of the two voltage ranges shown in Table 1. The IMS B300 must be earthed
via the mains cable supplied. A mains fuse should be fitted to the power inlet module, rated as shown in Table 1. The