CYIL2SM1300AA
Slave Mode
In slave mode, the register values of res_length and tint_timer are ignored. The integration time is controlled by the int_time pin. The
relationship between the input pin and the integration time is shown in Figure 14. When the input pin int_time is asserted, the pixel
array goes out of reset and exposure can begin. When int_time goes low again and the desired exposure time is reached, the image
is sampled and read out can begin.
Figure 14. Integration and Image Readout in Slave Mode
Changing a pixel's reset level during line readout might result in image artefacts during a small transient period. As a result, it is advised
to only change the value of int_time during ROT.
Triggered Shutter
The two main differences in the pipelined shutter mode are:
■ One single image is read upon every user action.
■ Integration (and read out) is under control of the user through pin int_time.
This means that for every frame, you need to manually intervene. The pixel array is kept in reset state until you assert the int_time
input. Similar to the pipelined shutter mode, there is a master mode in which the sequencer can control the integration time, or a slave
mode in which you can define the integration time.
Figure 15. Integration and Readout for Triggered Shutter
int_time1
Int. Time
Handling
Reset Exposure Time N
Reset
Exposure Time N Reset
Readout
Handling
ROT
Line
Readout
FOT Readout N
FOT
Read
outN+1
N+1
The possible applications for this triggered shutter mode are:
■ Synchronize external flash with exposure
■ Apply extremely long integration times (only in slave mode)
Document Number: 001-24599 Rev. *B
Page 20 of 41