CY2305, CY2309
Switching Characteristics for CY2305SC-1 and CY2309SC-1 Commercial Temperature
Devices
Parameter[9]
Name
Test Conditions
Min Typ. Max
Unit
t6B
t7
tJ
tLOCK
Delay, REF rising edge to
CLKOUT rising edge[8]
Measured at VDD/2. Measured in
1
PLL Bypass Mode, CY2309 device
5
8.7
ns
only.
Device-to-device skew[8]
Measured at VDD/2 on the
CLKOUT pins of devices
700
ps
Cycle-to-cycle jitter[8]
Measured at 66.67 MHz, loaded
70
200
ps
outputs
PLL lock time[8]
Stable power supply, valid clock
1.0
ms
presented on REF pin
Switching Characteristics for CY2305SC-1H and CY2309SC-1H Commercial Temperature
Devices
Parameter[9]
Name
Description
Min Typ. Max
Unit
t1
Output frequency
30 pF load
10 pF load
10
100
MHz
10
133.33
MHz
tDC
Duty cycle[8] = t2 ÷ t1
Measured at 1.4 V, Fout = 66.67 MHz 40.0 50.0 60.0
%
tDC
Duty cycle[8] = t2 ÷ t1
Measured at 1.4 V, Fout < 50 MHz
45.0
50.0 55.0
%
t3
Rise time[8]
Measured between 0.8 V and 2.0 V –
1.50
ns
t4
Fall time[8]
Measured between 0.8 V and 2.0 V –
1.50
ns
t5
Output-to-output skew[8]
All outputs equally loaded
85
250
ps
t6A
Delay, REF rising edge to
CLKOUT rising edge[8]
Measured at VDD/2
±350
ps
t6B
t7
t8
tJ
tLOCK
Delay, REF rising edge to
CLKOUT rising edge[8]
Device-to-device skew[8]
Output slew rate[8]
Cycle-to-cycle jitter[8]
PLL lock time[8]
Measured at VDD/2. Measured in
1
PLL Bypass Mode, CY2309 device
only.
Measured at VDD/2 on the CLKOUT
pins of devices
Measured between 0.8 V and 2.0 V 1
using Test Circuit #2
Measured at 66.67 MHz, loaded
outputs
Stable power supply, valid clock
presented on REF pin
5
8.7
700
60
200
1.0
ns
ps
V/ns
ps
ms
Operating Conditions for CY2305SI-XX and CY2309SI-XX Industrial Temperature Devices
Parameter
VDD
TA
CL
CL
CIN
Description
Supply voltage
Operating temperature (ambient temperature)
Load capacitance, below 100 MHz
Load capacitance, from 100 MHz to 133 MHz
Input capacitance
Min
Max
Unit
3.0
3.6
V
–40
85
°C
30
pF
10
pF
7
pF
Notes
8. Parameter is guaranteed by design and characterization. Not 100% tested in production.
9. All parameters specified with loaded outputs.
Document Number : 38-07140 Rev. *M