19-3975; Rev 0; 4/06
Dual-Channel, Platinum RTD-to-Voltage
Signal Conditioner
General Description
The MAX6603 dual-channel, platinum RTD-to-voltage
signal conditioner excites and amplifies the signal from
two external 200platinum-resistive temperature
devices (Pt RTD) to achieve high-voltage, level-filtered
signals for temperature measurements. The MAX6603
provides a direct ratiometric output voltage to simplify
the interface to microcontrollers with integrated analog-
to-digital converters (ADCs). External precision resis-
tors and calibration processes are not needed. The
MAX6603 provides the necessary signal-conditioning
functions, including ratiometric excitation current,
amplification, buffered voltage outputs, diagnostic fault
detections, and input protection. The MAX6603 ampli-
fies signals from two RTDs operating over the -40°C to
+1000°C temperature range and provides the tempera-
ture information as two independent analog voltages.
The MAX6603 features a ±6°C (max) accuracy over the
+400°C to +600°C temperature range.
The MAX6603 has overvoltage protection up to +16V
on RTD inputs, and ±5kV electrostatic discharge (ESD)
protection at RTD input pins for reliable operation
where RTD temperature-sensing probes are used. The
MAX6603 monitors the RTD for faults and asserts the
respective DG output low for fault conditions. The ana-
log voltage outputs can be readily connected to a vari-
ety of microcontrollers.
The MAX6603 is available in a small, 10-pin TDFN-EP
package and operates over the -40°C to +125°C auto-
motive temperature range from a single +3V to +5.5V
power supply.
Applications
Automotive Exhaust Temperature Monitoring
Engine Control Management to Meet EURO IV
Regulations
Braking Systems
Industrial Temperature Sensors
Food Transportation Monitoring Systems
Industrial Process Measurements
Features
Amplifies Pt RTD Temperature Signals
±5kV ESD Protection on RTD Inputs
+16V Overvoltage Fault Protection on RTD Inputs
Low RTD Excitation Current Minimizes Self-
Heating Errors
Small, 10-Pin TDFN Package
Fully Ratiometric Operation
No Calibration Required for Standard RTDs
RTD Diagnostic Check
High Accuracy: ±6°C (max) from +400°C to +600°C
Ordering Information
PART
MAX6603ATB+
PIN-PACKAGE
10 TDFN-EP*
RTD
200**
PKG
CODE
T1033-1
Note: Device is specified over the -40°C to +125°C tempera-
ture range.
*EP = Exposed pad.
+Denotes lead-free package.
**Other base resistance values can be accommodated.
Contact the factory for more information.
TOP VIEW
Pin Configuration
VCC 1 +
RS2- 2
RS2+ 3
RS1+ 4
RS1- 5
MAX6603
10 DG2
9 OUT2
8 OUT1
7 DG1
6 GND
TDFN
3mm x 3mm x 0.8mm
________________________________________________________________ Maxim Integrated Products 1
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]