CY6264
Selection Guide
Maximum Access Time
Maximum Operating Current
Maximum Standby Current
Shaded areas contain advance information.
Commercial
Industrial
Commercial
Industrial
CY6264-55
CY6264-70
Unit
55
70
ns
100
100
mA
200
20/15
20/15
mA
30
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage to Ground Potential ............... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State[1] ............................................ –0.5V to +7.0V
DC Input Voltage[1]......................................... –0.5V to +7.0V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage........................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA
Operating Range
Range
Commercial
Industrial
Ambient
Temperature
0°C to +70°C
–40°C to +85°C
VCC
5V ± 10%
Electrical Characteristics Over the Operating Range
6264-55
Parameter
Description
Test Conditions
Min. Max.
VOH
Output HIGH Voltage VCC = Min., IOH = –4.0 mA
VOL
Output LOW Voltage VCC = Min., IOL = 8.0 mA
VIH
Input HIGH Voltage
VIL
Input LOW Voltage[1]
IIX
Input Load Current GND < VI < VCC
IOZ
Output Leakage
GND < VI < VCC,
Current
Output Disabled
2.4
0.4
2.2
VCC
–0.5
0.8
–5
+5
–5
+5
IOS
Output Short
Circuit Current[2]
VCC = Max.,
VOUT = GND
ICC
VCC Operating
VCC = Max.,
Supply Current
IOUT = 0 mA
Com’l
Ind’l
–300
100
ISB1
Automatic CE1
Max. VCC, CE1 > VIH,
Com’l
20
Power–Down Current Min. Duty Cycle=100%
Ind’l
ISB2
Automatic CE1
Max. VCC, CE1 > VCC – 0.3V, Com’l
15
Power–Down Current VIN > VCC – 0.3V or VIN < 0.3V Ind’l
Shaded areas contain advance information.
Notes:
1. Minimum voltage is equal to–3.0V for pulse durations less than 30 ns.
2. Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
6264-70
Min. Max.
2.4
0.4
2.2
VCC
–0.5
0.8
–5
+5
–5
+5
–300
100
200
20
40
15
30
Unit
V
V
V
V
µA
µA
mA
mA
mA
mA
Document #: 001-02367 Rev. **