SM8750AV
Converter Coefficient Measurement Mode
When the serial interface bit GMES is set HIGH,
converter coefficient measurement mode is invoked.
In this mode, a voltage equivalent to a phase differ-
ence of ±0.5T, determined by the POLAR input bit,
is output on TVOUT. Internally, the difference in
pulsewidth between the charge/discharge signals is
±1T, where the charge pump circuit capacitance is
double the capacitance during normal operation in
order to generate outputs equivalent to phase differ-
ences of ±0.5T.
START
RDCLK
Internal charge signal
Internal discharge signal
TVOUT output
VREF2
Conversion voltage
(corresponds to −0.5T)
Reset
VREF2
Figure 3. Converter coefficient measurement mode timing (POLAR = LOW)
START
RDCLK
Internal charge signal
Internal discharge signal
TVOUT output
VREF2
Conversion voltage
(corresponds to +0.5T)
Reset
VREF2
Figure 4. Converter coefficient measurement mode timing (POLAR = HIGH)
NIPPON PRECISION CIRCUITS—8