NB100LVEP56
Table 1. PIN FUNCTION DESCRIPTION
Pin No.
ÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁÁ TSSOP
QFN
Name
I/O
14,20 3,9,18,19,
VCC
20
Default
State
Description
Positive Supply Voltage. All VCC Pins must be Externally
Connected to Power Supply to Guarantee Proper Operation.
11
15,24
VEE
Negative Supply Voltage. All VEE Pins must be Externally
Connected to Power Supply to Guarantee Proper Operation.
3,8
6,12
VBB0,
VBB1
ECL Reference Voltage Output
1
4
D0a
ECL Input
Low
Noninverted Differential Data a Input to MUX 0. Internal 75 kW to
VEE.
2
5
D0a
ECL Input
High
Inverted Differential Data a Input to MUX 0. Internal 75 kW to VEE
and 37 kW to VCC.
4
7
D0b
ECL Input
Low
Noninverted Differential Data b Input to MUX 0. Internal 75 kW to
VEE.
5
8
D0b
ECL Input
High
Inverted Differential Data b Input to MUX 0. Internal 75 kW to VEE
and 37 kW to VCC.
6
10
D1a
ECL Input
Low
Noninverted Differential Data a Input to MUX 1. Internal 75 kW to
VEE.
7
11
D1a
ECL Input
High
Inverted Differential Data a Input to MUX 1. Internal 75 kW to VEE
and 37 kW to VCC.
9
13
D1b
ECL Input
Low
Noninverted Differential Data b Input to MUX 1. Internal 75 kW to
VEE.
10
14
D1b
ECL Input
High
Inverted Differential Data b Input to MUX 1. Internal 75 kW to VEE
and 37 kW to VCC.
19
2
Q0
ECL Output
Noninverted Differential Output MUX 0. Typically Terminated with
50 W to VTT = VCC 2.0 V.
18
1
Q0
ECL Output
Inverted Differential Output MUX 0. Typically Terminated with
50 W to VTT = VCC 2.0 V.
13
17
Q1
ECL Output
Noninverted Differential Output MUX 1. Typically Terminated with
50 W to VTT = VCC 2.0 V.
12
16
Q1
ECL Output
Inverted Differential Output MUX 1. Typically Terminated with
50 W to VTT = VCC 2.0 V.
17
23
SEL0
ECL, CMOS
Low
Noninverted Differential Select Input to MUX 0. Internal 75 W to
Input
VEE.
16
22
COM_SEL ECL, CMOS
Low
Noninverted Differential Common Select Input to Both MUX.
Input
Internal 75 W to VEE.
15
21
SEL1
ECL, CMOS
Low
Noninverted Differential Select Input to MUX 1. Internal 75 W to
Input
VEE.
N/A
EP
Exposed Pad. (Note 1)
1. The thermally conductive exposed pad on the package bottom (see case drawing) must be attached to a heat sinking conduit.
http://onsemi.com
2