datasheetbank_Logo
データシート検索エンジンとフリーデータシート

AD5764(RevPrC) データシートの表示(PDF) - Analog Devices

部品番号
コンポーネント説明
一致するリスト
AD5764 Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
AD5764
Pin No.
18
19
20
21
22
23
24
25
26
27
28
29
32
Mnemonic
VOUTD
VOUTC
AGNDC
AGNDB
VOUTB
VOUTA
AGNDA
REFAB
REFCD
REFOUT
REFGND
TEMP
BIN/2sCOMP
Preliminary Technical Data
Function
Analog Output Voltage of DAC D. Buffered output with a nominal full-scale output
range of ±10 V. The output amplifier is capable of directly driving a 10 kΩ, 200 pF
load.
Analog Output Voltage of DAC C. Buffered output with a nominal full-scale output
range of ±10 V. The output amplifier is capable of directly driving a 10 kΩ, 200 pF
load.
Ground Reference Pin for DAC C Output Amplifier.
Ground Reference pin for DAC B Output Amplifier.
Analog Output Voltage of DAC B. Buffered output with a nominal full-scale output
range of ±10 V. The output amplifier is capable of directly driving a 10 kΩ, 200 pF
load.
Analog Output Voltage of DAC A. Buffered output with a nominal full-scale output
range of ±10 V. The output amplifier is capable of directly driving a 10 kΩ, 200 pF
load.
Ground Reference Pin for DAC A Output Amplifier.
External Reference Voltage Input for Channels A and B. Reference input range is 1 V
to 5 V; programs the full-scale output voltage. REFIN = 5 V for specified performance.
External Reference Voltage Input for Channels C and D. Reference input range is 1 V
to 5 V; programs the full-scale output voltage. REFIN = 5 V for specified performance.
Reference Output. This is the buffered reference output from the internal voltage
reference. The internal reference is 5 V ± 1 mV, with a reference tempco of 10
ppm/°C.
Reference Ground Return for the Reference Generator and Buffers.
This pin provides an output voltage proportional to temperature. The output
voltage is 750 mV typical at 25°C; variation with temperature is 10 mV/°C.
Determines the DAC Coding. When set to a logic high, input coding is offset binary;
0x0000 outputs negative full-scale and 0xFFFF outputs positive full-scale. Invoking a
CLR in this mode sets the output to negative full-scale. When set to a logic low, input
coding is twos complement; 0x8000 outputs negative full-scale, 0x0000 outputs 0V,
and 0x7FFF outputs positive full-scale. Invoking a CLR in this mode sets the output
to 0 V.
Rev. PrC 21-Oct-04| Page 12 of 28

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]