ABSOLUTE MAXIMUM RATINGSc
PARAMETER
CHG_IN to G
BAT, SYS, BTR, ISET, DCCC, ACIN, CHGLEV, EN, TH, nACOK, nSTAT1, nSTAT2,
nSTAT3, nBLV1, nBLV2 to G
Input Current
Output Current (Internal Limit) BAT to SYS
Maximum Junction Temperature
Storage Temperature
Lead Temperature (Soldering, 10 sec)
ACT3780
Rev 8, 09-Jul-13
VALUE
-0.3 to + 14
-0.3 to + 6
3.5
4
-40 to 150
-60 to 150
300
UNIT
V
V
A
A
°C
°C
°C
c: Do not exceed these limits to prevent damage to the device. Exposure to absolute maximum rating conditions for long periods may
affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCHG_IN = 5.0V, RISET = 1k, RBTR = 62k, RDCCC = 18.7k, TA = 25°C, unless otherwise specified.)
PARAMETER
SYMBOL
TEST CONDITIONS
ActivePath
CHG_IN Voltage Range
CHG_IN UVLO Voltage
CHG_IN UVLO Hysteresis
CHG_IN OVP Threshold
CHG_IN OVP Hysteresis
CHG_IN Supply Current
VCHG_IN
VUVLO Voltage Rising
VHYS(UVLO)
VOVP Voltage Rising
VHYS(OVP)
VCHG_IN = 6V, VBAT float
ISUP(CHG_IN) VCHG_IN = 6V, VBAT = 4.3V, ActivePathTM
Enabled and SYS No Load, Charger
in EOC or Time Out state or Disabled.
CHG_IN to SYS On-Resistance RDSON_Q1 ISYS = 100mA
IAC ACIN = 1
CHG_IN to SYS Current Limit
ACIN = G, CHGLEV = G
IUSB
ACIN = G, CHGLEV = SYS
SYS and DCCC Regulation
SYS Regulated Voltage
VSYS_REG ISYS = 100mA
DCCC Pull-Up Current
IDCCC
MIN TYP MAX UNIT
4.35
12
V
3.65 3.85 4.05 V
1.25
V
6.60 6.90 7.20 V
360
mV
60 200 µA
1.8
mA
0.3 0.5
2.5
A
80 90 100 mA
400 450 500 mA
4.4 4.6 4.8
V
90 100 110 µA
Innovative PowerTM
-4-
Active-Semi ProprietaryFor Authorized Recipients and Customers
ActivePathTM is a trademark of Active-Semi.
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.

Share Link: 