STV6412A
Electrical characteristics
Table 8. Slow blanking section (continued)
Symbol
Parameter
SLBmed Output medium level (ext. 16/9)
SLBhigh Output high level (ext. 4/3)
Test condition
Min. Typ. Max. Unit
5 5.75 6.5 V
10 11 12 V
Table 9. Fast blanking section
Symbol
Parameter
Test condition
Min. Typ. Max. Unit
Input mode
FBlow/high Input low/high level threshold
0.4 0.7 0.9 V
IIN
Input current
Output mode
2 10 µA
FBLOW
FBHIGH
Output low level
Output high level
t(s) FBDEL Fast blanking RGB delay
roduc FBTRANS FB transitions at FB output
Rise Time
P Fall Time
lete Table 10. C_Gate function output
o Symbol
Parameter
bs C_GATE-H Pull-up resistor value to VCCB1
O C_GATE-L Output low level
t(s) - Interrupt output (refer to Note 1)
uc Symbol
Parameter
rod IT-Leak High level leakage
P IT-Low Output low level (active)
lete Table 11. Address selection input
soSymbol
Parameter
ObADDsel_L Address selection low level
RLOAD = 150 Ω
0.5 V
3.0 3.4 3.8 V
At 50% on digital RGB transients,
at 2 V on FB rise transient, at 1 V
on FB fall, CLOAD = 10pF
15
ns
maximum
CLOAD = 10 pF maximum
between 10% and 90%
between 90% and 10%
10
ns
10
ns
Test condition
IIN = 0 mA
IIN = 1 mA
Test condition
External pull-up to 5 V
IIN = 0 mA
IIN = 1 mA
Test condition
Min. Typ. Max. Unit
20
kΩ
0.3 V
0.7 V
Min. Typ. Max. Unit
10 µA
0.3 V
0.7 V
Min. Typ. Max. Unit
0 0.2 V
ADDsel_H Address selection high level
ILEAK Leakage current
2.5
VDD V
10 µA
Note: 1 The interrupt is forced to a low level when a change is detected on slow blanking inputs. It