16 Megabit FlashBank Memory
SST38VF166
Data Sheet
TABLE 6: SOFTWARE COMMAND SEQUENCE FOR FLASH BANKS
1st Bus Cycle 2nd Bus Cycle 3rd Bus Cycle 4th Bus Cycle 5th Bus Cycle 6th Bus Cycle
Command Code Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2
Software ID Entry 5555H AAH 2AAAH 55H 5555H 90H
3
Software ID Exit 5555H AAH 2AAAH 55H 5555H F0H
4
Flash Bank
Word-Program
5555H AAH 2AAAH 55H 5555H A0H
WA5
Data
In
Flash Bank
Sector-Erase
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H SA6 30H
Flash Bank
Block-Erase
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H BA6 50H
Flash Bank
Bank-Erase
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H 5555H 10H
CFI Entry
5555H AAH 2AAAH 55H 5555H 98H
7
CFI Exit
5555H AAH 2AAAH 55H 5555H F0H
4
1. Command Code Address format A14-A0 (Hex), Addresses > A14 are Dont Carefor Command sequences
2. Data format DQ7 -DQ0 (Hex), DQ15 - DQ8 are Dont Care
3. With A14-A1 = 0; SST Manufacturers ID = 00BFH, is read with A0 = 0
SST38VF166 Device ID = 2791H, 2792H, and 2793H is read with A0 = 1 for the applicable BE# active
4. The device does not remain in Software Product ID Mode or CFI Mode if powered down.
5. WA = Word address
6. SA = Sector address
BA = Block address
7. There is a separate CFI for each bank. See Tables 8 through 16
T6.4 327
TABLE 7: SOFTWARE COMMAND SEQUENCE FOR E2 BANKS
1st Bus Cycle 2nd Bus Cycle 3rd Bus Cycle 4th Bus Cycle 5th Bus Cycle 6th Bus Cycle
Command Code Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2
Software ID Entry 5555H AAH 2AAAH 55H 5555H 90H
3
Software ID Exit 5555H AAH 2AAAH 55H 5555H F0H
4
E2 Bank
Word-Write
5555H AAH 2AAAH 55H 5555H A0H
WA5
Data
In
E2 Bank
Word-Program
5555H AAH 2AAAH 55H 5555H A5H
WA5
Data
In
E2 Bank
Sector-Erase
E2 Bank
Bank-Erase
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H SA6 30H
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H 5555H 10H
E2 Bank
OTP Enable
5555H AAH 2AAAH 55H 5555H 80H 5555H AAH 2AAAH 55H 5555H 70H
CFI Entry
5555H AAH 2AAAH 55H 5555H 98H
7
CFI Exit
5555H AAH 2AAAH 55H 5555H F0H
4
1. Command Code Address format A14-A0 (Hex), Addresses > A14 are Dont Carefor Command sequences
2. Data format DQ7 -DQ0 (Hex), DQ15 - DQ8 are Dont Care
3. With A14-A1 = 0; SST Manufacturers ID = 00BFH, is read with A0 = 0
SST38VF166 Device ID = 2791H, 2792H, and 2793H is read with A0 = 1 for the applicable BE# active
4. The device does not remain in Software Product ID Mode or CFI Mode if powered down.
5. WA = Word address
6. SA = Sector address
7. There is a separate CFI for each bank. See Tables 8 through 16