ABRIDGED DATA SHEET
DS28E01-100
1Kb Protected 1-Wire EEPROM
with SHA-1 Engine
ELECTRICAL CHARACTERISTICS (continued)
(TA = -40°C to +85°C.) (Note 1)
Note 17: ε in Figure 12 represents the time required for the pullup circuitry to pull the voltage on IO up from VIL to VTH. The actual
maximum duration for the master to pull the line low is tW1LMAX + tF - ε and tW0LMAX + tF - ε, respectively.
Note 18: δ in Figure 12 represents the time required for the pullup circuitry to pull the voltage on IO up from VIL to the input-high
threshold of the bus master. The actual maximum duration for the master to pull the line low is tRLMAX + tF.
Note 19: Current drawn from IO during the EEPROM programming interval or SHA-1 computation.
Note 20: Refer to the full data sheet for this note.
Note 21: Write-cycle endurance is degraded as TA increases.
Note 22: Not 100% production tested; guaranteed by reliability monitor sampling.
Note 23: Data retention is degraded as TA increases.
Note 24: Guaranteed by 100% production test at elevated temperature for a shorter time; equivalence of this production test to the
data sheet limit at operating temperature range is established by reliability testing.
Note 25: EEPROM writes can become nonfunctional after the data-retention time is exceeded. Long-term storage at elevated tem-
peratures is not recommended; the device can lose its write capability after 10 years at +125°C or 40 years at +85°C.
Note 26: Refer to the full data sheet for this note.
COMPARISON TABLE
LEGACY VALUES
DS28E01-100 VALUES
PARAMETER
STANDARD SPEED
(μs)
OVERDRIVE SPEED
(μs)
STANDARD SPEED
(μs)
OVERDRIVE SPEED
(μs)
tSLOT (including tREC)
tRSTL
tPDH
tPDL
tW0L
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
61
(undefined)
7
(undefined)
65*
(undefined)
11*
(undefined)
480
(undefined)
48
80
480
640
48
80
15
60
2
6
15
60
2
6
60
240
8
24
60
240
8
24
60
120
6
16
60
120
6
15.5
*Intentional change; longer recovery time requirement due to modified 1-Wire front-end.
Note: Numbers in bold are not in compliance with legacy 1-Wire product standards.