Secondary Control for Energy-Saving AC Adaptor MM1548
Operation
Voltage between VCC and OUT(200mV)
RLS
470
Supply transistor
RLB
100
VCC
CNT
OUT
Load current
200mV
Input/output difference control
Voltage drop detection
(V=4.6V)
ROS1
PC1
200mV Load current detection
Voltage drop detection
(VCC=3.5V)
REF
Overvoltage
detection
115mV Energy saving current detection
Constant voltage control
ROS2
(VCC, OUT=7V)
Energy saving mode
Normal mode
(VCC=5.1V)
Energy saving mode control
(3.5V :ON, 5.1V :OFF)
Photocoupler-turn-off(4.6V )
Constant current control
(CS=114.4mV)
(Io=520mA)
PO1 drive(Load 5k)
PO1 drive
Photocoupler PC1 control
PO1
GND
CS
RCS
0.22
Output
(+)
()
1. Operation of Blocks
1.1 Input/output difference control
In the normal mode that a load current is detected and the system supplies the load current through the
Supply Transistor (PNP type), MM1548 controls CNT current flowing into the base of Supply Transistor to
keep the differential voltage between VCC and OUT (Vce of Supply Transistor) at 200mV.
1.2 Load current detection and Energy saving current detection
When load current increases in energy saving mode and the differential voltage between VCC and OUT
exceeds VLSP1 (200mV), MM1548 changes to the normal mode, PO1 switches from open to low mode,
and the photocoupler PC1turns on. As a result, the system switches primary-side switching operation to
normal mode from disabled.
The switching voltage has following hysteresis if load current is increasing ( VLSP1) or decreasing
( VLSP2).
( hysteresis: VLSP1 = 200mV < > VLSP2 = 115mV)
When the differential voltage between VCC and OUT falls to VLSP2 (115mV), MM1548 changes to the
energy saving mode, and the photocoupler-turn-off circuit switches compulsory photocoupler current to
zero under the condition that load current is decreasing in normal mode and Vcc = 4.6V or more.
1.3 Voltage drop detection
When VCC voltage falls to 4.6V in the energy saving mode, MM1548 stops the photocoupler-turn-off circuit
operation to save consumption current of MM1548.
When VCC voltage falls to 3.5V in the energy saving mode, MM1548 changes to the normal mode.
As a result, Out voltage (output of secondary side) swings intermittent between 4.9V and 3.5V.
1.4 Constant current control
When load current is increasing in the normal mode, and the differential voltage between CS and GND
exceeds VCS1(114.4mV typ.), PO1 switches from open to low mode, and the photocoupler PC1 turns on. As
a result, MM1548 changes to the CC(constant current) mode, and the load current is controlled that CS
voltage keeps VCS1.
1.5 Constant voltage control
When MM1548 is in normal mode and isn't in constant current mode, it is in CV(constant voltage) mode,
and PO1 current is controlled that VCC voltage keeps 5.1V (equal to internal 1.25V: REF voltage).