Secondary Control for Energy-Saving AC Adaptor MM1548
Absolute Maximum Ratings (Ta=25°C)
Item
Symbol
Ratings
Unit
Storage temperature
TSTG
–40~+125
°C
Operating temperature
TOPR
–30~+85
°C
Supply voltage
VCC max.
–0.3~+18
V
Allowable loss
Pd
150 (alone)
mW
Recommended Operating Conditions
Item
Symbol
Ratings
Unit
Operating temperature
TOPR
–30~+85
°C
Supply voltage
VOP
+2.5~+12
V
Electrical Characteristics (unless otherwise specified, Ta=+25°C, Vcc=4.9V)
Item
Symbol
Test Conditions
Min. Typ. Max. Unit.
Current consumption1(energy saving mode) ICC1
VCC=4.4V, VOUT=4.4V, VCS=0V
60 110 µA
Current consumption2(normal mode) ICC2
VCC=5.3V, VOUT=5.0V, VCS=0V
1.5 3.0 mA
Voltage control section
Output inversion voltage
VO
IIN=5mA, VOUT=VCC–0.3V, VCS=0V
4.99 5.10 5.21 V
OUT input sink current
IOUT
VCC=4.9V, VOUT=4.9V, VCS=0V
25 150 nA
PO1 output sink current 1
IPO1 VCC=5.3V, VOUT=5.0V, VCS=0V VPO1=0.5V 5 17
mA
Constant current control
Output inversion voltage 1
(Constant current control)
VCS1 VCC=4.9V, RCS1=1k, VOUT=4.6V, RCS2=40k, IIN=5mA 111.2 114.4 117.6 mV
Output inversion voltage 2
VCS2 VCC=2.0V, RCS1=1k, VOUT=0V, RCS2=40k, IIN=5mA 22 34
mV
(Constant current control drop)
CS input source current
ICS
VCC=4.9V, VOUT=4.6V, VCS=0.1V
5 100 nA
Power supply voltage rejection ratio PSRR2 VCC=3.7V 4.4V, VCS=VCS1–10mV, RL1=5k60 70
dB
PO1 output sink current 2
IPO2 VCC=4.9V, VOUT=4.6V, VCS=0.2V, VPO1=0.5V 5 17
mA
Input-output difference control
Input-output difference control voltage
VLS VCC=5.1V, RLS=4.7k, RLB=100, RO=5k140 200 260 mV
CNT output sink current
ICNT VCC=5.1V, VOUT=4.8V, VCS=0V, VCNT=0.8V 5 30
mA
Load detection
Load detection voltage
VLSP1 VCC=4.9V, RL1=47k, VOUT=4.9V L, VCS=0V 170 200 230 mV
Energy saving detection voltage
(load detection release voltage)
VLSP2 VCC=4.9V, RL1=47k, VOUT=L 4.9V, VCS=0V 85 115 145 mV
3.5V undervoltage detection VOL1 VCC=H L, RL1=10k, VOUT=VCC, VCS=0V 3.4 3.5 3.6 V
3.5V undervoltage detection hysteresis VOL1H VCC=L H, RL1=10k, VOUT=VCC, VCS=0V
350
mV
4.6V undervoltage detection VOL2 VCC=H L, RL1=47k, VOUT=VCC, VCS=0V 4.47 4.60 4.73 V
PO1 output sink current 3
IPO3 VCC=4.9V, VOUT=4.6V, VCS=0V, VPO2=1.0V 100 200 400 µA
PO1 output source current
IPO4 VCC=4.9V, VOUT=4.9V, VCS=0V, VPO2=4.6V 1.0 5.0
mA
Constant current mode selection
2pin(CNT pin) disable voltage VCNTO VCC=H L, VCNT=0.8V, VOUT=VCC–0.3V, VCS=0V, ICNT < 1mA
2.4
V
Constant current mode selection threshold
VCSS VCC=4.9V, RCS1=1k, VOUT=4.6V, RCS2=20k, IIN=5mA, VCS < VCS min.
0.6
V
(between VCC and OUT)