部品番号
コンポーネント説明
一致するリスト
MLX90308LDF
Melexis
Melexis Microelectronic Systems  Melexis
MLX90308LDF Datasheet PDF : 28 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MLX90308CCC
Programmable Sensor Interface
Alarm Option
This option allows controlling the low and high limits of
the output (See Figure 5.). The output level is set
when the output tries to exceed the programmed
limits. Five bytes are reserved for this option. The first
byte is the low trigger limit and the second the low
output. The third and fourth bytes are used for the high
limit and the output. The fifth byte is the alarm control,
used to select the alarm input. The different levels are
programmed as eight bit numbers. These correspond
to the 8 upper bits of the 10 bit signal measurement.
When the alarm mode is not used, all of the data is 0.
The control code is coded as shown in Table 7. The
six possible signals are listed below and are encoded
on the 4 MSB’s of byte 31 of the EEPROM.
Table 7. Alarm Source Bit Definition
Selected input
TPO
IAO
GNO
VMO
IO1
IO2
MUX Value
0010
0110
0000
0011
0100
0101
IO1 & IO2
IO1 and IO2 are used in the alarm and level steering
modes. For custom firmware, they can be used for a
digital input, an analog input, or a digital output.
Figure 6.
Alarm & Steering
Source Points
VBP
VBN
OFC
FLT
IAO
Offset
VDD1 FET VDD GND
Power Supply
Regulation
GNO
Gain
VM
VMO
TPO
TMP
Temp
Sense
& Amp
IO1
IO2
Bidirectional
I/O
ADC
&
DAC
UART
CM
CMO
CMN
Microcontroller
Core, Memory,
EEPROM
Reset,Test,&
Oscillator
TSTB
Figure 5.
COMS
Alarm Function
OUTPUT
High
Output
MLX90308
Figure 7. Level Steering
Function
IO1, IO2
MLX90308
1 -1
1-0
Low
Output
Low
Trigger
Input Signal
High
Trigger
M39L0X190029x0x3N08ame of Sensor Rev Y.X 22/Aug/98
Rev 004
Page P13age 13
0-1
0-0
(I02,I01)
Level 1
Level 2
Level 3
Aug/02