CS5376
SWITCHING CHARACTERISTICS (Continued)
MOSI Write Timing
Parameter
SSI Enable to Valid Latch Clock
Data Set-up Time Prior to SCK Rising
Data Hold Time After SCK Rising
SCK Falling Prior to SSI Disable
MISO Read Timing
SSI Enable to Valid Latch Clock
SCK Falling to New Data Bit
SSI Rising to MISO Hi-Z
Symbol Min
Typ
Max Unit
t3
50
-
t4
50
-
t5
100
-
t6
100
-
-
ns
-
ns
-
ns
-
ns
t7
-
-
150
ns
t8
-
-
150
ns
t9
-
-
150
ns
SSI
MOSI
SCLK
MSB MSB - 1
t3
t4
t5
t1 t2
LSB
t6
Figure 1. MOSI Write Timing in SPI Slave Mode (Not to Scale)
SSI
MISO
SCLK
t7
MSB MSB - 1
t8
t1 t2
t9
LSB
Figure 2. MISO Read Timing in SPI Slave Mode (Not to Scale)
DS256PP1
7