Q Series Data Sheet
®
66 132 Watt DC-DC Converters
Table 6b: Output data for double-output models with output 1 and output 2 in symmetrical or independent configuration.
General conditions as per table 5a
Output
48Q2660
24 V /24 V
BQ GQ2660
Unit
24 V /24 V
Characteristics
Conditions
Output 1
Output 2
Output 1
Output 2
min typ max min typ max min typ max min typ max
Vo
Output setting voltage1 Vi nom, Io nom
23.88
24.12 23.76
24.24 23.88
24.12 23.76
24.24 V
Vow Worstcase output
Vi min Vi max 23.64
24.36 see Output
23.64
24.36
see Output
voltage
TC min TC max
Voltage Regulation
Voltage Regulation
Vo P Overvoltage limitation Io = 0 – Io max
n.a.
27.5
30
n.a.
27.5
30
of second control loop
Io
Io nom
Io L
vo 4
Output current 2
Vi min Vi max
Nominal output current TC min TC max
Output current limit 2
Output Switch. frequ. Vi nom, Io nom
voltage
BW = 20 MHz
noise Total incl.spikes
0.4
2.2
4.6
10
20
4.0 0.4
4.0
2.2
6.2 4.6
6.2
25
10 25
40
20 40
0.4
5.1
2.2
5.8
8.0
10 25
20 40
0.4
5.1 A
2.2
5.8
8.0
10
25 mVpp
20 40
Po max Output power total 1
Vi min Vi max
TC min TC max
vo d 4
td 4 5
Dynamic Voltage
load
deviation
regulation Recovery
time
Vi nom
Io nom 1/2 Io nom
I o2 = 1/2 Io nom
±400
400
Vo tr Output via R-input 1.1Vi min-Vi max 14.4
voltage
0.1Io nom Io nom
trim range using opt. P TC min TC max
n.a.
αVo Temp. coefficient of Vo Ionom
TC min TC max
±0.02
106
132
±500
±400
±500
400
26.4
see Output
14.4 3
26.4
Voltage Regulation
21.6
26.4
±0.02
±0.02
see Output
Voltage Regulation
±0.02
W
mV
µs
V
%/K
1 If the output voltages are increased above Vo nom through R-input control, option P setting or remote sensing, the output power should be
reduced accordingly so that Po max and TC max are not exceeded.
2 See: Output Power at Reduced Temperature
3 For DQ2660 and EQ2660: 16.8 V
4 According to IEC/EN 61204
5 Recovery time until Vo remains within ±1% of Vo, see Dynamic load regulation
BCD20011- G Rev AG, 12-Mar-2012
Page 11 of 26