MP5006 – 5V, 1A- 5A PROGRAMMABLE CURRENT LIMIT SWITCH WITH AUTO ENABLE
There are 4 types of faults, and each fault has a
direct and indirect effect on the Enable/Fault pin
and the internal fault flag. In a typical application
there are one or more of the MP5006 chips in a
system. The Enable/Fault lines will typically be
connected together.
Fault description
Short/over current
Under Voltage
Over Voltage
Thermal Shutdown
Table 3Fault Function Influence in Application
Internal action
Limit current
Output is
turned off
Limit output
voltage
Shutdown part.
The part retries
to start up
automatically
Effect on Fault Pin
none
Internally drives
Enable/Fault pin to
Logic low
None
Internally drives
Enable/Fault pin
to low level, and
after part cools
down, Enable/Fault
pin will be pulled
high
Effect on Flag
None
Flag is reset
None
Flag is set at
thermal shut
down, and is set
to high after
auto start up.
Effect on secondary Part
none
Secondary part output is
disabled, and fault flag is
reset.
None
Secondary part output is
disabled when thermal shut
down, and is enabled after
MP5006 auto start up.