datasheetbank_Logo
データシート検索エンジンとフリーデータシート

ISL6112 データシートの表示(PDF) - Renesas Electronics

部品番号
コンポーネント説明
メーカー
ISL6112
Renesas
Renesas Electronics Renesas
ISL6112 Datasheet PDF : 30 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ISL6112
12VOUT
VSTBY
INT
100k
100k
100k
SCL
SDA
INT#
A2
A1
A0
DISABLING SMI WHEN HPI CONTROL IS USED
VSTBY
100k 9
100k 28
45
42
44
43
FORON#_A
FORON#_B
AUXENA
AUXENB
ONA
ONB
DISABLING HPI WHEN SMI CONTROL IS USED
FIGURE 27. I/O CONFIGURATION FOR DISABLING HPI/SMI CONTROL
12IOUT
12VGATE
3IOUT
3VOUT
CFILTER
CFILTER
3VGATE
FIGURE 28. 12VMAIN CR AND SHUT-DOWN
ISL6112 Bias, Power-On Reset, and Power
Cycling
The ISL6112 uses VSTBY as the only supply source. VSTBY is
required for proper operation of the ISL6112 SMBus and
registers and must be applied at all times. A Power-On-Reset
(POR) cycle is initiated after VSTBY rises above its UVLO threshold
and remains satisfied for 250µs. All internal registers are cleared
after POR. If VSTBY is recycled, the ISL6112 enters a new POR
cycle. VSTBY must be the first supply voltage applied, followed by
the MAIN supply inputs of 12VIN and 3VIN. The SMBus is ready
for access at the end of the POR cycle (250µs after VSTBY is
valid). During tPOR, all outputs remain off.
Enabling the VAUX Outputs
Upon asserting an AUXEN input, the related internal power switch
turns on, connecting the nominally 3.3V VSTBY supply to its VAUX
load. The turn-on is slew rate limited and invokes the current
FIGURE 29. 3VMAIN CR AND SHUT-DOWN
regulation feature so as not to droop the supply due to in-rush
current load. Figure 17 illustrates the VAUX turn-on performance
into a 10, 100µF load.
Standby Mode
Standby mode is entered when one or more of the MAIN supply
inputs (12VIN and/or 3VIN) is either absent, below its respective
UVLO threshold, or OFF. The ISL6112 also has 3.3V auxiliary
outputs (VAUXA and VAUXB), satisfying an optional PCI-Express
requirement. These outputs are fed from the VSTBY input pins.
They are independent of the MAIN outputs and are controlled by
the AUXEN input pins or via their respective bits in the control
registers. Should the MAIN supply inputs fall below their
respective UVLO thresholds, VAUX still functions, as long as
VSTBY is compliant. Prior to standby mode, ONA and ONB (or the
control register MAINA and MAINB bits) inputs must be
deasserted, or the ISL6112 asserts its FAULT outputs. If an
FN6456 Rev 1.00
August 25, 2011
Page 15 of 30

Share Link: 