datasheetbank_Logo
データシート検索エンジンとフリーデータシート

FED20-48S05W データシートの表示(PDF) - Astrodyne Corporation

部品番号
コンポーネント説明
一致するリスト
FED20-48S05W Datasheet PDF : 3 Pages
1 2 3
Isolated and Regulated 20 WATT Modular DC/DC Converters
FED20W series
INPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
I/P Voltage Range (24/48V Nom.) 9-36 / 18-75VDC
Voltage Surge (100mS max) 24 V: 50 VDC; 48 V: 100 VDC
Under Voltage Lockout
24 VDC I/P DC/DC ON: 9 VDC OFF: 7.5 VDC
48 VDC I/P DC/DC ON: 15 VDC OFF: 18 VDC
Input Filter
Pi Type
Input Voltage Variation (dv/dt) 5V/rms, max. to ETS300 132 part 4.4
Input Reflected Ripple Current 20mA p-p
Start Up Time (Power Up or RC) 20mS, typ.
On/Off Control Positive Logic: (Ref to - Input) is standard.
ON = Open or 3V < Vr < 12V
OFF = Short or 0V < Vr < 1.2V
Negative Logic: (optional)
ON = Short or 0V < Vr < 1.2V
OFF = Open or 3V < Vr < 12V
Efficiency
See Selection Chart
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
Load Regulation NL-FL
Singles: ±0.5%
Duals: ±1%
Cross Regulation (Dual 25%-FL) ±5%
Voltage Adjustability (Single O/P) ±10%
Line Regulation (Single/Dual) ±0.2% / ±0.5%
Temperature Coefficient
±0.02%/°C, max.
Ripple/Noise
See Selection Chart
Voltage Accuracy
± 1%
Transient Response Recovery
25% Load Step Change
250 microSeconds
Short Circuit Protection
Continuous Hiccup, self-recovering
Overvoltage Protection, Zener Diode Clamp:
3.3V Output
3.9Volts
5V Output
6.2Volts
12V Output
15Volts
15V Output
18Volts
Overload Protection
150% of FL Rating, typ.
Input-Out Isolation
In/Out Capacitance
Isolation Resistance
Switching Frequency
1600VDC
1500 pF, max.
10000 M Ohms
400Khz, typ
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
-40 to +105°C (see derate curve)
Relative Humidity
5-95%
Storage Temperature
-55 to +125°C *
Maximum Case Temp
105°C *
Thermal Impedance
Convection: 12°C/Watt
Convection w. Heatsink: 10°C/Watt
Thermal Shock
MIL-STD-810D
Vibration
10-55Hz 10G 30 min. on X, Y, Z axes
MTBF
BELLCORE TR-NWT-000322 Case 1: 50% Stress, Temp. @ 40°C
1.691 MHrs
MIL-HDBK-217F TA=25°C FL, Ground Benign, Controlled Environment
562.9 KHrs
EMI
EN55022A
ESD
EN61000-4-2 Criteria B
Radiated Immunity
EN61000-4-3 Criteria A
EFT
EN61000-4-4B Criteria B
Surge
EN61000-4-5B Criteria B
Conducted Immunity
EN61000-4-6A Criteria A
PHYSICAL SPECIFICATIONS
Case Material
Construction
Dimensions
Weight
Nickel-Coated Copper w. FR4 Base
Encapsulated w, UL94-V0 Epoxy
2”L x 1”W x 0.4”H
(50.8 x 25.4 x 10.2mm)
0.95oz (27g)
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458

Share Link: 