IDT54/74FCT521T/AT/BT/CT
FAST CMOS 8-BIT IDENTITY COMPARATOR
MILITARY AND COMMERCIAL TEMPERATURE RANGES
POWER SUPPLY CHARACTERISTICS
Symbol
Parameter
Test Conditions(1)
Min. Typ.(2) Max.
ICC
ICCD
IC
Quiescent Power Supply
Current TTL
Inputs HIGH
Dynamic Power Supply Current(4)
Total Power Supply Current(5)
VCC = Max.
VIN = 3.4V(3)
VCC = Max.
Outputs Open
One Input Toggling
50% Duty Cycle
VCC = Max.
Outputs Open
fi = 10MHz
One Bit Toggling
50% Duty Cycle
VIN = VCC
VIN = GND
VIN = VCC
VIN = GND
VIN = 3.4V
VIN = GND
— 0.5 2.0
— 0.15 0.25
— 1.5 3.5
— 1.8 4.5
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient.
3. Per TTL driven input (VIN = 3.4V). All other inputs at VCC or GND.
4. This parameter is not directly testable, but is derived for use in Total Power Supply Calculations.
5. Values for these conditions are examples of the ICC formula. These limits are guaranteed but not tested.
6. IC = IQUIESCENT + IINPUTS + IDYNAMIC
IC = ICC + ICC DHNT + ICCD (fCP/2 + fiNi)
ICC = Quiescent Current
ICC = Power Supply Current for a TTL High Input (VIN = 3.4V)
DH = Duty Cycle for TTL Inputs High
NT = Number of TTL Inputs at DH
ICCD = Dynamic Current Caused by an Input Transition Pair (HLH or LHL)
fCP = Clock Frequency for Register Devices (Zero for Non-Register Devices)
fi = Input Frequency
Ni = Number of Inputs at fi
All currents are in milliamps and all frequencies are in megahertz.
Unit
mA
mA/
MHz
mA
2572 tbl 06
SWITCHING CHARACTERISTICS OVER OPERATING RANGE
IDT54/74FCT521T IDT54/74FCT521AT IDT54/74FCT521BT IDT54/74FCT521CT
Symbol
Parameter
Com'l. Mil. Com'l. Mil. Com'l. Mil. Com'l. Mil.
Condition(1) Min.(2) Max. Min.(2) Max. Min.(2) Max. Min.(2) Max. Min.(2) Max. Min.(2) Max. Min.(2) Max. Min.(2) Max. Unit
tPLH Propagation
tPHL Delay
An or Bn to
CL = 50pF
1.5 11.0 1.5 15.0 1.5 7.2 1.5 9.5 1.5 5.5 1.5 7.3 1.5 4.5 1.5 5.1 ns
RL = 500
OA = B
tPLH Propagation
tPHL Delay
1.5 10.0 1.5 9.0 1.5 6.0 1.5 7.8 1.5 4.6 1.5 6.0 1.5 4.1 1.5 4.5 ns
IA = B to
OA = B
NOTES:
1. See test circuit and waveforms.
2. Minimum limits are guaranteed but not tested on Propagation Delays.
2572 tbl 07
6.16