MP5007 – 5V, 1A- 5A PROGRAMMABLE CURRENT LIMIT SWITCH
The Enable/Fault line must be above the mid
level for the output to be turned on.
The fault flag is a internal flip-flop that can be set
or reset under various conditions:
1. Thermal Shutdown: set fault flag
2. Under Voltage: reset fault flag
3. Low voltage on Enable/Fault pin: reset
fault flag
4. Mid voltage on Enable/Fault pin: no
effect
Under a fault, the Enable/Fault pin is driven to
the mid level.
There are 4 types of faults, and each fault has a
direct and indirect effect on the Enable/Fault pin
and the internal fault flag. In a typical application
there are one or more of the MP5007 chips in a
system. The Enable/Fault lines will typically be
connected together.
Fault description
Short/over current
Under Voltage
Over Voltage
Thermal Shutdown
Table3 — Fault Function Influence in Application
Internal action
Effect on Fault
Pin
Effect on
Flag
Effect on secondary Part
Limit current
Output is turned off
Limit output voltage
Shutdown part. The
part is latched off
until a UVLO or
externally driven to
ground.
none
Internally drives
Enable/Fault pin to
Logic low
None
Internally drives
Enable/Fault pin
to mid level
none
Flag is
reset
None
Flag is Set
none
Secondary part output is
disabled, and fault flag is
reset.
None
Secondary part output is
disabled.
Under Voltage Lock Out Operation
If the supply (input) is below the UVLO threshold,
the output is disabled, and the fault line is driven
low.
When the supply goes above the UVLO
threshold, the output is enabled and the fault line
is released. When the fault line is released, EN
will be pulled high by a 28uA current source. No
external pull up resistor is required. In addition,
the pull up voltage is limited to 5 volts.
Thermal Protection
When thermal protection is triggered, the output
is disabled and the fault line is driven to the mid
level. The thermal fault condition is latched
(meaning the fault flag is set), and the part will
remain latched off until the fault (enable) line is
brought low. Cycling the power below the UVLO
threshold will also reset the fault flag.
MP5007 Rev.1.1
www.MonolithicPower.com
9
9/2/2014
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2014 MPS. All Rights Reserved.