PRELIMINARY
CY6264
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage to Ground Potential ............... –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State[1] ............................................ –0.5V to +7.0V
DC Input Voltage[1]......................................... –0.5V to +7.0V
Output Current into Outputs (LOW)............................. 20 mA
Static Discharge Voltage .......................................... >2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current .................................................... >200 mA
Operating Range
Range
Commercial
Ambient
Temperature
0°C to +70°C
VCC
5V ± 10%
Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
VOH
Output HIGH Voltage VCC = Min., IOH = –4.0 mA
VOL
Output LOW Voltage
VCC = Min., IOL = 8.0 mA
VIH
Input HIGH Voltage
VIL
Input LOW Voltage[1]
IIX
Input Load Current
GND < VI < VCC
IOZ
Output Leakage
GND < VI < VCC,
Current
Output Disabled
IOS
Output Short
Circuit Current[2]
VCC = Max.,
VOUT = GND
ICC
VCC Operating
VCC = Max.,
Supply Current
IOUT = 0 mA
ISB1
Automatic CE1
Max. VCC, CE1 > VIH,
Power–Down Current Min. Duty Cycle=100%
ISB2
Automatic CE1
Max. VCC, CE1 > VCC – 0.3V,
Power–Down Current VIN > VCC – 0.3V or VIN < 0.3V
Shaded area contains advanced information.
6264-55
6264-70
Min. Max. Min. Max. Unit
2.4
2.4
V
0.4
0.4
V
2.2
VCC
2.2
VCC
V
–0.5
0.8
–0.5
0.8
V
–5
+5
–5
+5
µA
–5
+5
–5
+5
µA
–300
–300 mA
100
100
mA
20
20
mA
15
15
mA
Capacitance[3]
Parameter
Description
Test Conditions
CIN
COUT
Input Capacitance
Output Capacitance
TA = 25°C, f = 1 MHz,
VCC = 5.0V
Notes:
1. Minimum voltage is equal to -3.0V for pulse durations less than 30 ns.
2. Not more than 1 output should be shorted at one time. Duration of the short circuit should not exceed 30 seconds.
3. Tested initially and after any design or process changes that may affect these parameters.
Max.
7
7
Unit
pF
pF
AC Test Loads and Waveforms
5V
OUTPUT
R1 481
5V
OUTPUT
R1 481
30 pF
INCLUDING
JIG AND
SCOPE (a)
R2
255
5 pF
INCLUDING
JIG AND
SCOPE (b)
R2
255
CY6264-3
Equivalent to:
THÉVENIN EQUIVALENT
OUTPUT
167
1.73V
3.0V
10%
GND
< 5 ns
ALL INPUT PULSES
90%
90%
10%
< 5 ns
CY6264-4