Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM50RSD120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
50 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
IGBT Inverter Sector
Collector Cutoff Current
Diode Forward Voltage
Collector-Emitter Saturation Voltage
Inductive Load Switching Times
ICES
VEC
VCE(sat)
ton
trr
tC(on)
toff
tC(off)
VCE = VCES, Tj = 25°C, VD = 15V
—
VCE = VCES, Tj = 125°C, VD = 15V
—
-IC = 50A, VD = 15V, VCIN = 15V
—
VD = 15V, VCIN = 0V, IC = 50A,
—
Pulsed, Tj = 25°C
VD = 15V, VCIN = 0V, IC = 50A,
—
Pulsed, Tj = 125°C
0.5
VD = 15V, VCIN = 0 ~ 15V
—
VCC = 600V, IC = 50A
—
Tj = 125°C, Inductive Load
—
—
IGBT Brake Sector
Collector Cutoff Current
FWDi Forward Voltage
Collector-Emitter Saturation Voltage
Control Sector
ICES
VFM
VCE(sat)
VCE = VCES, Tj = 25°C, VD = 15V
—
VCE = VCES, Tj = 125°C, VD = 15V
—
IF = 15A
—
VD = 15V, VCIN = 0V, IC = 15A,
—
Pulsed, Tj = 25°C
VD = 15V, VCIN = 0V, IC = 15A,
—
Pulsed, Tj = 125°C
Over Current Trip Level Inverter Part
OC
(VD = 15V)
Over Current Trip Level Brake Part
OC
Short Circuit Trip Level Inverter Part
SC
Tj = 25°C
93
Tj = 125°C
59
-20°C ≤ Tj ≤ 125°C, VD = 15V
22
-20°C ≤ Tj ≤ 125°C, VD = 15V
—
Short Circuit Trip Level Brake Part
—
Over Current Delay Time
Over Temperature Protection (VD = 15V)
toff(OC)
OT
VD = 15V
—
Trip Level
111
(Lower Arm)
Supply Circuit Under Voltage Protection
OTR
UV
Reset Level
—
Trip Level
11.5
(-20 ≤ Tj ≤ 125°C)
UVR
Reset Level
—
Circuit Current
Input ON Threshold Voltage
ID
VCIN(on)
VD = 15V, VCIN = 15V, VN1-VNC
—
VD = 15V, VCIN = 15V, VXP1-VXPC
—
Applied between UP-VUPC, VP-VVPC, 1.2
Input OFF Threshold Voltage
Fault Output Current*
VCIN(off)
IFO(H)
IFO(L)
WP-VWPC, UN, VN, WN, Br -VNC
1.7
VD = 15V, VCIN = 15V
—
VD = 15V, VCIN = 15V
—
Minimum Fault Output Pulse Width*
tFO
VD = 15V
1.0
*Fault output is given only when the internal OC, SC, OT and UV protections schemes of either upper or lower arm device operate to protect it.
Typ.
—
—
2.5
2.4
2.1
1.0
0.15
0.4
2.5
0.7
—
—
2.5
2.5
2.2
157
—
—
183
95
10
118
100
12.0
12.5
44
13
1.5
2.0
—
10
1.8
Max. Units
1.0
mA
10
mA
3.5
Volts
3.2
Volts
2.8
Volts
2.5
µS
0.3
µS
1.0
µS
3.5
µS
1.2
µS
1.0
mA
10
mA
3.5
Volts
3.3
Volts
3.2
Volts
— Amperes
— Amperes
— Amperes
— Amperes
— Amperes
—
µS
125
°C
—
°C
12.5 Volts
—
Volts
60
mA
18
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
—
mS
3