Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PM50RSD120
Intellimod™ Module
Three Phase + Brake IGBT Inverter Output
50 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
IGBT Inverter Sector
Collector Cutoff Current
Diode Forward Voltage
Collector-Emitter Saturation Voltage
Inductive Load Switching Times
ICES
VEC
VCE(sat)
ton
trr
tC(on)
toff
tC(off)
VCE = VCES, Tj = 25°C, VD = 15V
VCE = VCES, Tj = 125°C, VD = 15V
-IC = 50A, VD = 15V, VCIN = 15V
VD = 15V, VCIN = 0V, IC = 50A,
Pulsed, Tj = 25°C
VD = 15V, VCIN = 0V, IC = 50A,
Pulsed, Tj = 125°C
0.5
VD = 15V, VCIN = 0 ~ 15V
VCC = 600V, IC = 50A
Tj = 125°C, Inductive Load
IGBT Brake Sector
Collector Cutoff Current
FWDi Forward Voltage
Collector-Emitter Saturation Voltage
Control Sector
ICES
VFM
VCE(sat)
VCE = VCES, Tj = 25°C, VD = 15V
VCE = VCES, Tj = 125°C, VD = 15V
IF = 15A
VD = 15V, VCIN = 0V, IC = 15A,
Pulsed, Tj = 25°C
VD = 15V, VCIN = 0V, IC = 15A,
Pulsed, Tj = 125°C
Over Current Trip Level Inverter Part
OC
(VD = 15V)
Over Current Trip Level Brake Part
OC
Short Circuit Trip Level Inverter Part
SC
Tj = 25°C
93
Tj = 125°C
59
-20°C Tj 125°C, VD = 15V
22
-20°C Tj 125°C, VD = 15V
Short Circuit Trip Level Brake Part
Over Current Delay Time
Over Temperature Protection (VD = 15V)
toff(OC)
OT
VD = 15V
Trip Level
111
(Lower Arm)
Supply Circuit Under Voltage Protection
OTR
UV
Reset Level
Trip Level
11.5
(-20 Tj 125°C)
UVR
Reset Level
Circuit Current
Input ON Threshold Voltage
ID
VCIN(on)
VD = 15V, VCIN = 15V, VN1-VNC
VD = 15V, VCIN = 15V, VXP1-VXPC
Applied between UP-VUPC, VP-VVPC, 1.2
Input OFF Threshold Voltage
Fault Output Current*
VCIN(off)
IFO(H)
IFO(L)
WP-VWPC, UN, VN, WN, Br -VNC
1.7
VD = 15V, VCIN = 15V
VD = 15V, VCIN = 15V
Minimum Fault Output Pulse Width*
tFO
VD = 15V
1.0
*Fault output is given only when the internal OC, SC, OT and UV protections schemes of either upper or lower arm device operate to protect it.
Typ.
2.5
2.4
2.1
1.0
0.15
0.4
2.5
0.7
2.5
2.5
2.2
157
183
95
10
118
100
12.0
12.5
44
13
1.5
2.0
10
1.8
Max. Units
1.0
mA
10
mA
3.5
Volts
3.2
Volts
2.8
Volts
2.5
µS
0.3
µS
1.0
µS
3.5
µS
1.2
µS
1.0
mA
10
mA
3.5
Volts
3.3
Volts
3.2
Volts
— Amperes
— Amperes
— Amperes
— Amperes
— Amperes
µS
125
°C
°C
12.5 Volts
Volts
60
mA
18
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
mS
3

Share Link: 