FUNCTION DIAGRAM
SUPPLY 4.25V
VOLTAGE
MITSUBISHI Dig./Ana.INTERFACE
M51943AGP
VOLTAGE DETECTING, SYSTEM RESETTING IC SERIES
H
OUTPUT
STATE
L
ABSOLUTE MAXINUM RATINGS (Ta=25°C Unless otherwise noted)
Symbol
ICC
Isink
VO
Pd
Parameter
Supply Voltage
Output Sink Current
Output Voltage
Power Dissipation
Test condition
Output with constant current load
5pin SOP(SOT-25)
K 0-
Topr
Tstg
Thermal Derating
Operating Temperature
Storage Temperature
Ta≥25°C
5pin SOP
Ratings
18
6
Vcc
200
2
-30 to +85
-40 to +125
Unit
V
mA
V
mW
mW/°C
°C
°C
ELECTRICAL CHARACTERISTICS (Ta=25°C, Unless otherwise noted)
Symbol
Parameter
VS
∆VS
VS/∆T
ICC
Vsat
VOPL
IOC
VOH
tPHL
tPLH
Detecting Voltage
Hysterisis Voltage
Detecting Voltage
Temperature Coefficient
Circut Current
Output Saturation Voltage
Threshold
Operating Voltage
Output Load Current
Output High Voltage
Propagation Deray Time
Test condition
VCC=5V
VCC=4V,Isink=4mA
Minimum supply voltage RL=2.2kΩ,Vsat≤0.4V
for IC operation
RL=100kΩ,Vsat≤0.4V
VCC=5V,VO=1/2Vcc
Response time when Vcc changes H to L
Response time when Vcc changes L to H
MIN
4.05
30
-40
Vcc-0.2
Limits
TYP
4.25
50
0.01
370
0.2
0.67
0.55
-25
Vcc-0.06
6
3
MAX
4.45
80
560
0.4
0.8
0.7
-17
Unit
V
mV
%/°C
µA
V
V
µA
V
µs
(2/3)