datasheetbank_Logo
データシート検索エンジンとフリーデータシート

STTH30R06CW データシートの表示(PDF) - STMicroelectronics

部品番号
コンポーネント説明
一致するリスト
STTH30R06CW
ST-Microelectronics
STMicroelectronics ST-Microelectronics
STTH30R06CW Datasheet PDF : 5 Pages
1 2 3 4 5
Fig. 1: Conduction losses versus average current
(per leg).
P(W)
40
35
30
25
20
15
10
5
0
0
2
δ = 0.05 δ = 0.1 δ = 0.2
δ = 0.5
δ=1
T
IF(av)(A)
δ=tp/T
tp
4
6
8
10 12 14 16 18 20
STTH30R06CW
Fig. 2: Forward voltage drop versus forward
current (per leg).
IFM(A)
120
110
100
90
80
70
60
50
40
30
20
10
0
0
1
Tj=125°C
(Maximum values)
Tj=125°C
(Typical values)
VFM(V)
2
3
4
Tj=25°C
(Maxumim values)
5
6
Fig. 3: Relative variation of thermal impedance
junction to case versus pulse duration.
Zth(j-c)/Rth(j-c)
1.0
0.9
0.8
0.7
0.6 δ = 0.5
0.5
0.4 δ = 0.2
0.3 δ = 0.1
0.2
Single pulse
0.1
0.0
1.E-03
1.E-02
tp(s)
T
1.E-01
δ=tp/T
tp
1.E+00
Fig. 4: Peak reverse recovery current versus
dIF/dt (90% confidence, per leg).
IRM(A)
30
VR=400V
Tj=125°C
25
20
IF=0.5 x IF(av)
15
IF=0.25 x IF(av)
10
IF=2 x IF(av)
IF=IF(av)
5
dIF/dt(A/µs)
0
0
200
400
600
800
1000
Fig. 5: Reverse recovery time versus dIF/dt
(90% confidence, per leg).
trr(ns)
100
90
80
70
60
50
40
30
20
10
0
0
IF=0.5 x IF(av)
IF=IF(av)
dIF/dt(A/µs)
200
400
600
VR=400V
Tj=125°C
IF=2 x IF(av)
800
1000
Fig. 6: Reverse recovery charges versus dIF/dt
(90% confidence, per leg).
Qrr(nC)
800
700
VR=400V
Tj=125°C
600
500
400
300
200
100
0
0
200
IF=2 x IF(av)
IF=IF(av)
IF=0.5 x IF(av)
dIF/dt(A/µs)
400
600
800
1000
3/5