datasheetbank_Logo
データシート検索エンジンとフリーデータシート

PS21564 データシートの表示(PDF) - Mitsumi

部品番号
コンポーネント説明
一致するリスト
PS21564 Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
PS21564
TRANSFER-MOLD TYPE
INSULATED TYPE
THERMAL RESISTANCE
Symbol
Parameter
Condition
Limits
Min.
Typ.
Max. Unit
Rth(j-f)Q
Rth(j-f)F
Junction to case thermal
Inverter IGBT part (per 1/6 module)
resistance
(Note 3) Inverter FWDi part (per 1/6 module)
4.5 °C/W
6.5 °C/W
Note 3: Grease with good thermal conductivity should be applied evenly with about +100µm~+200µm on the contacting surface of DIP-IPM
and heat-sink.
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
VCE(sat)
VEC
ton
trr
tc(on)
toff
tc(off)
ICES
Collector-emitter saturation
voltage
FWDi forward voltage
Switching times
Collector-emitter cut-off
current
Condition
VD = VDB = 15V
IC = 15A, Tj = 25°C
VIN = 5V
IC = 15A, Tj = 125°C
Tj = 25°C, IC = 15A, VIN = 0V
VCC = 300V, VD = VDB = 15V
IC = 15A, Tj = 125°C, VIN = 0 5V
Inductive load (upper-lower arm)
VCE = VCES
Tj = 25°C
Tj = 125°C
Limits
Min.
Typ.
Max. Unit
1.45 1.95
1.55 2.05
V
1.50 2.00
V
0.60
1.20
1.80
µs
0.30
µs
0.40
0.60
µs
1.50
2.10
µs
0.50
0.80
µs
1
mA
10
CONTROL (PROTECTION) PART
Symbol
Parameter
Condition
Limits
Unit
Min.
Typ.
Max.
ID
Circuit current
VD = VDB = 15V Total of VP1-VNC, VN1-VNC
VIN = 5V
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
VD = VDB = 15V Total of VP1-VNC, VN1-VNC
5.00 mA
0.40 mA
7.00 mA
VIN = 0V
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS
0.55 mA
VFOH
VFOL
Fault output voltage
VSC = 0V, FO circuit pull-up to 5V with 10k
VSC = 1V, IFO = 1mA
4.9
V
0.95
V
VSC(ref) Short circuit trip level
Tj = 25°C, VD = 15V
(Note 4)
0.43
0.48
0.53
V
IIN
Input current
VIN = 5V
1.0
1.5
2.0
mA
UVDBt
Trip level
10.0
12.0
V
UVDBr
UVDt
Supply circuit under-voltage
protection
Tj 125°C
Reset level
Trip level
10.5
12.5
V
10.3
12.5
V
UVDr
Reset level
10.8
13.0
V
tFO
Fault output pulse width
CFO = 22nF
(Note 5)
1.0
1.8
ms
Vth(on)
Vth(off)
ON threshold voltage
OFF threshold voltage
Applied between UP, VP, WP-VNC, UN, VN, WN-VNC
2.1
2.3
2.6
V
0.8
1.4
2.1
V
Note 4 : Short circuit protection is functioning only at the low-arms. Please select the value of the external shunt resistor such that the SC trip-
level is less than 25.5 A.
5 : Fault signal is output when the low-arms short circuit or control supply under-voltage protective functions operate. The fault output pulse-
width tFO depends on the capacitance value of CFO according to the following approximate equation : CFO = 12.2 10-6 tFO [F].
Jul. 2003

Share Link: 