RT9519B
Charge State Indicator
Charge State
Charging
Charging Suspended by
Thermal Loop
Safety Timers Expired
Charging Done
Recharging after
Termination
IC Disabled or no Valid
Input Power
CHG Output
Low
(for first charge cycle)
2Hz Flash
High Impedance
Battery Pack Temperature Monitoring
The battery pack temperature monitoring function can be
realized by connecting the TS pin to an external Negative
Temperature Coefficient (NTC) thermistor to prevent over
temperature condition. Charging is suspended when the
voltage at the TS pin is out of normal operating range. The
internal timer is then paused, but the value is maintained.
When the TS pin voltage returns back to normal operating
range, charging will resume and the safe charge timer will
continue to count down from the point where it was
suspended. Note that although charging is suspended due
to the battery pack temperature fault, the CHG pin will
continue to remain low and indicate charging.
VP
VP
R1
0.74 x VP -
TS
+
R2
RNTC
-
+
0.28 x VP
Too Cold
Too Hot
Figure 1
Too Cold Temperature
RCOLD = RNTC
Too Hot Temperature
RHOT = RNTC
R2 + RCOLD = 0.74
(1)
RCOLD + R1 + R2
R2 + RHOT = 0.28
(2)
RHOT + R1 +R2
DS9519B-01 April 2011
From (1), (2)
R1 = RCOLD RHOT
2.457
R2 = 0.389 ×R1RHOT
If R2 < 0
RCOLD = 0.74
(3)
RCOLD + R1
From (3)
R1
=
RCOLD
0.74
RCOLD
Charge Enable
When EN is low, the charger turns on. When EN is high,
the charger turns off. EN is pulled low for initial condition.
VIN input Current Limit
ISETL
ISETU
L
L
L
H
H
X
VIN Input Current
Lim it
95 mA
47 5mA
1 .5A
Suspend Mode
Set USUS = H, and the charge will enter Suspend Mode.
In the Suspend Mode, CHG is in high impedance and
IUSUS(MAX) < 300μA.
Power Switch
For the RT9519B, there are three power scenarios:
(1)When a battery and an external power supply (USB or
adapter) are connected simultaneously :
If the system load requirements exceed that of the input
current limit, the battery will be used to supplement the
current to the load. However, if the system load
requirements are less than that of the input current limit,
the excess power from the external power supply will be
used to charge the battery.
(2)When only the battery is connected to the system :
The battery provides the power to the system.
(3)When only an external power supply is connected to
the system :
www.richtek.com