Customer:
Part No.: CRGH Series
High Power Thick Film Chip Resistors
7. Performance specification :
Characteristics
Limits
Test Methods
( JIS C 5201-1 )
Dielectric
withstanding
voltage
No evidence of flashover
mechanical damage, arcing or
insulation break down
4.7 Clamped in the trough of a 90°C metallic v-block and
shall be tested at ac potential respectively specified in
the type for 60-70 seconds
4.8 Natural resistance change per temp. degree centigrade.
Temperature
Coefficient
See Page 2
R2-R1 x 106 (PPM/°C)
R1(t2-t1)
R1: Resistance value at room temperature (T1)
R2: Resistance value at room temp. plus 100°C (T2)
Test pattern: room temp. (T1), room temp. +100°C (T2)
Short time
Overload
Resistance change rate is
± 5% (2.0% + 0.1Ω) Max.
± 1% (1.0% + 0.1Ω) Max.
4.13 Permanent resistance change after the application
of a potential of 2.5 times RCWV for 5 seconds.
Wave Solder:
Test temperature of solder:
245°C ±3°C dipping time in solder : 2-3 seconds.
Reflow Solder:
Solderability 95 % coverage Min.
Soldering heat
Resistance change rate is:
±(1%+0.05Ω) Max.
Temperature
cycling
Resistance Change Rate Is
± 5% (1.0% + 0.05W) Max.
± 1% (0.5% + 0.05W) Max.
Humidity
Load life in
Humidty
Load Life
Terminal Bending
Resistance change rate is
± 5% (3.0% + 0.1W) Max.
± 1% (1.0% + 0.1W) Max.
Resistance change rate is
± 5% (3.0% + 0.1W) Max.
± 1% (1.0% + 0.1W) Max.
Resistance change rate is
± 5% (3.0% + 0.1W) Max.
± 1% (1.0% + 0.1W) Max.
Resistance change rate is
± (1.0% + 0.05W) Max.
1773204-1
4.18 Dip the resistor into a solder bath having a temperature
of 260°C ± 3°C and hold it for 10 ± 1 seconds.
4.19 Resistance change after continuous
5 cycles for duty cycle specified below :
Step Temperature
Time
1
-55°C ± 3°C
2
Room temp.
30 mins
10 ~ 15 mins
3
+155°C ± 2°C
30 mins
4
Room temp.
10 ~ 15 mins
4.24 Temporary resistance change after 240 hours
exposure in a humidity test chamber controlled at
40±2°C and 90-95% relative humidity
7.9 Resistance change after 1,000 hours (1.5 hours "on",
0.5 hour "off" ) at RCWV in a humidity chamber
controlled at 40°C ± 2°C and 90 to 95% relative humidity
4.25.1 Permanent resistance change after 1,000 hours
operating at RCWV, with duty cycle of
(1.5 hours"on", 0.5 hour"off") at 70°C ± 2°C ambient
4.33 Twist of Test Board :
Y/X = 3/90 mm for 60 seconds
Page 6.