MTD 800
(Preliminary)
Bit
15
14
13
12
11
10- 8
7
6
5
4
3
Symbol
RxS
EIEN
RFCEN
NDFA
RBLEN
Description
Receive Status. When “1”, indicates the receive process is running.
When “0”, indicate the receive process is stopped. This is a read-only bit
and the default value is “0”.
Early Interrupt Enable. When set, the chip will work under early interrupt
mode. When cleared, it will operate in normal interrupt mode. The default
value is “0”.
Receive Flow Control packet Enable. When set, the flow control packet
will be recognized during full duplex operation. When cleared, it will be
considered as a normal packet. The default value is “0”, but may be
changed by loading from EEPROM.
Not Defined Flow control Address. For the legacy flow control device, a
802.3x special DA was not defined at that time. For the reason of back-
ward compatibility, only the length/type field is checked when this bit is
set. The default value is “0”.
Receive Burst Length Enable. When set, the receive burst transaction will
use the following receive programmable burst length. When cleared, the
PBL defined in the bus command register will be adopted. The default
value is “1”.
Receive Programmable Burst Length
RPBL2 RPBL1 RPBL0 Length
0
0
0
1 words
0
0
1
4
0
1
0
8
RPBL[2:0] 0
1
1
16
1
0
0
32
1
0
1
64
1
1
0
128
1
1
1
512
PROM
AB
AM
ARP
The default value is “011”.
Promiscuous Mode Bit. If PROM equals to 1, all valid packets with any
physical destination address are accepted. If PROM equals to 0, the
physical address of incoming packet must match the node address pro-
grammed in the PAR0 ~ 5, otherwise it will be rejected. The default value
is “0”.
Accept Broadcast Bit. If AB equals to 1, all packets with broadcast desti-
nation address are accepted. If AB equals to 0, any packet with broadcast
address is rejected. The default value is “1”.
Accept Multicast Bit. If AM equals to 1, all packets with desired multicast
destination address are accepted. If AM equals to 0, any packet with mul-
ticast address is rejected. The default value is “1”.
Reserved.
Accept Runt Packet. If ARP equals to 1, all packets with their length less
than 64 bytes are accepted. If ARP equals to 0, any packet whose length
is less than 64 bytes is rejected. The default value is “0”.
26/42
MTD800 Revision 0.0 07/20/1999