datasheetbank_Logo
データシート検索エンジンとフリーデータシート

B59100M1060A070 データシートの表示(PDF) - EPCOS AG

部品番号
コンポーネント説明
一致するリスト
B59100M1060A070 Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
Sensors
Motor protection, single sensors
M1100
Reliability data
Test
Electrical endurance,
cycling
Electrical endurance,
constant
Damp heat
Standard
IEC 60738-1
IEC 60738-1
IEC 60738-1
Rapid change
of temperature
Vibration
IEC 60738-1
IEC 60738-1
Test conditions
Room temperature, Vmax; Rseries = 50
Number of cycles: 100
Storage at Vmax /Top,max (Vmax)
Test duration: 1000 h
Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
T1 = Top,min (0 V), T2 = Top,max (0 V)
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, test Na
Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 × 2 h
Test according to IEC 60068-2-6, test Fc
R25/R25
< 25%
< 25%
< 10%
< 25%
< 5%