4. FLY WHEEL OPERATION
The flywheel logic will check the incoming video data for
valid video lines. If the incoming data represents a valid
line, the flywheel remains in sync with the incoming data. If
the incoming data represents an invalid line, the flywheel
will use the stored timing information for the past valid line
to generate the output HVF timing signals until three (3)
consecutive lines having identical timing are detected. In
this case, the new timing information will be saved and the
flywheel operation is updated to this new timing.
Mismatches between the HVF information decoded from
the data stream and that indicated by the flywheel will
trigger the EAV_ERR and SAV_ERR signals as shown in
Figure 3. HVF output timing is shown in Figure 2.
5. AUTOMATIC SWITCH LINE LOCK HANDLING
The automatic switch line lock is based on the assumption
that the switching of video sources will only cause the H
signal to be out of alignment whereas V and F signals
remain in sync; i.e. switching between video sources of the
same format. Therefore, when in the automatic switch line
lock mode (FAST_LOCK transitions for low to high), the
flywheel positive H signal transition will align with the
detected positive H signal transition. Timing for the
FAST_LOCK signal is shown in Figure 5.
TABLE 1: Source Format Parameters
Reference SMPTE
Standard
260m 260m 295m 274m 274m 274m 274m 274m 274m 274m 274m 296m 296m
Format ID
A
B
C
D
E
F
G
H
I
J
K
L
M
Lines/Frame
1125 1125 1250 1125 1125 1125 1125 1125 1125 1125 1125 750 750
Words/Active Line
(each channel Y,
Cb/Cr)
1920 1920 1920 1920 1920 1920 1920 1920 1920 1920 1920 1280 1280
Total Active Lines
1035 1035 1080 1080 1080 1080 1080 1080 1080 1080 1080 720 720
Words/Total Line
(each channel Y,
Cb/Cr)
2200 2200 2376 2200 2200 2640 2200 2200 2640 2750 2750 1650 1650
Frame Rate (Hz)
30 30/M 25
30 30/M 25
30 30/M 25
24 24/M 60 60/M
Fields /Frame
2
2
2
2
2
2
1
1
1
1
1
1
1
Data Rate Divisor
1
M
1
1
M
1
1
M
1
1
M
1
M
NOTE: M=1.001 in the above table.