datasheetbank_Logo
データシート検索エンジンとフリーデータシート

MX641 データシートの表示(PDF) - CML Microsystems Plc

部品番号
コンポーネント説明
一致するリスト
MX641
CML
CML Microsystems Plc CML
MX641 Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Dual SPM Detector
Page 9 of 16
MX641 Preliminary Information
4.3.1.1 Controlled Sensitivity Setting Information
The sensitivity figures in Table 4 are based on the following:
1. The recommended amplifier components (see Figure 2) are used, providing an amplifier gain at 16kHz
of 19.8dB ±0.3dB or at 12kHz of 19.1dB ±0.3dB.
2. A comparator sensitivity of 1.6dB(ref.) ±1dB (the variation is due to filter gain error, filter output offset,
comparator input offset or a combination of all 3).
3. The applied VDD is 5.0 volts; 0dB (ref.) = 775mVRMS.
Serial Data
Bits
D5 - D1
00000
00001
00010
00011
00100
00101
00110
00111
01000
01001
01010
01011
01100
01101
01110
01111
10000
10001
10010
10011
10100
10101
10110
10111
11000
11001
11010
11011
11100
11101
11110
11111
12kHz System
Bit D0 = ‘1’
16kHz System
Bit D0 = ‘0’
Bandpass
Filter Gain
Minimum
Sensitivity
Nominal
Sensitivit
y
Maximum
Sensitivity
Minimum
Sensitivity
Nominal
Sensitivit
y
Maximum
Sensitivity
(dB)
dB(ref.)
dB(ref.)
dB(ref.)
dB(ref.)
dB(ref.)
dB(ref.)
0
-16.2
-17.5
-18.8
-16.9
-18.2
-19.5
1.0
-17.2
-18.5
-19.8
-17.9
-19.2
-20.5
2.0
-18.2
-19.5
-20.8
-18.9
-20.2
-21.5
3.0
-19.2
-20.5
-21.8
-19.9
-21.2
-22.5
4.0
-20.2
-21.5
-22.8
-20.9
-22.2
-23.5
5.0
-21.2
-22.5
-23.8
-21.9
-23.2
-24.5
6.0
-22.2
-23.5
-24.8
-22.9
-24.2
-25.5
7.0
-23.2
-24.5
-25.8
-23.9
-25.2
-26.5
8.0
-24.2
-25.5
-26.8
-24.9
-26.2
-27.5
9.0
-25.2
-26.5
-27.8
-25.9
-27.2
-28.5
10.0
-26.2
-27.5
-28.8
-26.9
-28.2
-29.5
11.0
-27.2
-28.5
-29.8
-27.9
-29.2
-30.5
12.0
-28.2
-29.5
-30.8
-28.9
-30.2
-31.5
13.0
-29.2
-30.5
-31.8
-29.9
-31.2
-32.5
14.0
-30.2
-31.5
-32.8
-30.9
-32.2
-33.5
15.0
-31.2
-32.5
-33.8
-31.9
-33.2
-34.5
16.0
-32.2
-33.5
-34.8
-32.9
-34.2
-35.5
17.0
-33.2
-34.5
-35.8
-33.9
-35.2
-36.5
18.0
-34.2
-35.5
-36.8
-34.9
-36.2
-37.5
19.0
-35.2
-36.5
-37.8
-35.9
-37.2
-38.5
20.0
-36.2
-37.5
-38.8
-36.9
-38.2
-39.5
21.0
-37.2
-38.5
-39.8
-37.9
-39.2
-40.5
22.0
-38.2
-39.5
-40.8
-38.9
-40.2
-41.5
23.0
-39.2
-40.5
-41.8
-39.9
-41.2
-42.5
24.0
-40.2
-41.5
-42.8
-40.9
-42.2
-43.5
25.0
-41.2
-42.5
-43.8
-41.9
-43.2
-44.5
26.0
-42.2
-43.5
-44.8
-42.9
-44.2
-45.5
27.0
-43.2
-44.5
-45.8
-43.9
-45.2
-46.5
These states should never be used. If sensitivities of this order are required (e.g. the Swedish Rural
SPM specification), it is recommended that the Controlled Sensitivity setting be set to 20dB (10100)
and external components selected to set the Input Amp gain to a higher figure. This action will
prevent falsing by sub-harmonic frequencies.
Table 4: Controlled Sensitivity Setting Information
ã2001 MX-COM, Inc.
www.mxcom.com tel: 800 638 5577 336 744 5050 fax: 336 744 5054
Doc. # 20480115.004
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA All trademarks and service marks are held by their respective companies.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]