datasheetbank_Logo
データシート検索エンジンとフリーデータシート

MX629 データシートの表示(PDF) - CML Microsystems Plc

部品番号
コンポーネント説明
メーカー
MX629 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Delta Modulation CODEC
J/P LH
Name
20 22 Clock Mode 2
21 23 Clock Mode 1
22 24 VDD
5
MX629
Signal
power
Description
Clock rates refer to f = 1024MHz Xtal/Clock input. During internal
operation the data clock frequencies are available at the ports for
external circuit synchronization. Independent or common data
rate inputs to Encode and Decode data clock ports may be
employed in the External Clocks mode. Internal 1M pullups.
See Table 3.
Positive Supply. A single 5.0V supply is required.
Table 1: Signal List
Data Enable
1
0
1
Powersave
1
1
0
Encoder Output
Enable
High Z (open circuit)
VSS
Table 2: Encoder Output
Clock Mode 1
0
0
1
1
Clock Mode 2
0
1
0
1
Facility
External Clocks
Internal, 64kbps = f/16
Internal, 32kbps = f/32
Internal, 16kbps = f/64
Table 3: Clock Mode
1998 MX-COM, Inc.
www.mxcom.com Tel: 800 638 5577 336 744 5050 Fax: 336 744 5054
Doc. # 20480190.001
4800 Bethania Station Road, Winston-Salem, NC 27105-1201 USA All Trademarks and service marks are held by their respective companies.