MITSUBISHI INTELLIGENT POWER MODULES
PM400DVA060
FLAT-BASE TYPE
INSULATED PACKAGE
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ.
Control Sector
Short Circuit Trip Level
Short Circuit Current Delay Time
Over Temperature Protection
SC
toff(SC)
OT
-20°C ≤ Tj ≤ 125°C, VD = 15V
VD = 15V
Trip Level
650
910
—
10
100
110
(VD = 15V, Lower Arm)
OTr
Supply Circuit Under Voltage Protection
UV
Reset Level
Trip Level
85
95
11.5
12.0
(-20°C ≤ Tj ≤ 125°C)
UVr
Reset Level
—
Circuit Current
ID
VD = 15V, VCIN = 5V, VN1-VNC
—
VD = 15V, VCIN = 5V, VP1-VPC
—
Input ON Threshold Voltage
Vth(on)
Applied between
1.2
Input OFF Threshold Voltage
Vth(off)
CP1-VPC, CN1-VNC
1.7
Fault Output Current
IFO(H)
VD = 15V, VFO = 15V*
—
IFO(L)
VD = 15V, VFO = 15V*
—
Minimum Fault Output Pulse Width
tFO
VD = 15V*
1.0
SXR Terminal Output Voltage
VSXR
Tj ≤ 125°C, Rin = 6.8kΩ (SPR, SNR) 4.5
* Fault output is given only when the internal SC, OT, and UV protections circuits of either an upper-arm or a lower-arm device operate to protect it.
12.5
23
23
1.5
2.0
—
10
1.8
5.1
Max. Units
— Amperes
—
µs
120
°C
105
°C
12.5 Volts
—
Volts
30
mA
30
mA
1.8
Volts
2.3
Volts
0.01
mA
15
mA
—
ms
5.6
Volts
Sep.1998