MITSUBISHI <INTELLIGENT POWER MODULES>
PM400DVA060
FLAT-BASE TYPE
INSULATED PACKAGE
TOTAL SYSTEM
Symbol
Parameter
Condition
Supply Voltage Protected by VD = 13.5 ~ 16.5V, Inverter Part,
VCC(PROT) SC
Tj = 125°C Start
VCC(surge) Supply Voltage (Surge)
Applied between : C1-E2, Surge value or without
switching
Module Case Operating
TC
Temperature
(Note-1)
Tstg
Storage Temperature
Viso
Isolation Voltage
60Hz, Sinusoidal, Charged part to Base, AC 1 min.
(Note-1) TC measurement point is below. (3mm depth at the center of the side of base plate)
Ratings
400
500
–20 ~ +100
–40 ~ +125
2500
Unit
V
V
°C
°C
Vrms
Tc
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
VCE(sat)
VEC
ton
trr
tc(on)
toff
tc(off)
ICES
Collector-Emitter
Saturation Voltage
FWDi Forward Voltage
Switching Time
Collector-Emitter
Cutoff Current
CONTROL PART
Test Condition
Min.
VD = 15V, IC = 400A
Tj = 25°C
—
VCIN = 0V
Tj = 125°C
—
–IC = 400A, VD = 15V, VCIN = 5V
—
0.4
VD = 15V, VCIN = 0V↔5V
—
VCC = 300V, IC = 400A
—
Tj = 125°C
—
Inductive Load (upper and lower arm)
—
VCE = VCES, VCIN = 5V
Tj = 25°C
—
Tj = 125°C
—
Symbol
Parameter
Test Condition
ID
Circuit Current
VD = 15V, VCIN = 5V
Vth(ON)
Vth(OFF)
SC
toff(SC)
OT
OTr
UV
UVr
IFO(H)
IFO(L)
tFO
VSXR
Input ON Threshold Voltage
Input OFF Threshold Voltage
Short Circuit Trip Level
Short Circuit Current Delay
Time
Over Temperature Protection
(Lower-arms only)
Supply Circuit Under-Voltage
Protection
Applied between : CPI-VPC, CNI -VNC
–20≤ Tj ≤ 125°C, VD = 15V
VD = 15V
Base-plate
Temperature detection, VD = 15V
–20 ≤ Tj ≤ 125°C
Fault Output Current
VD = 15V, VFO = 15V
Minimum Fault Output Pulse
Width
SXR Terminal Output Voltage
VD = 15V
–20 ≤ Tj ≤ 125°C, Rin=6.8kΩ
(Note-2) Fault output is given only when the internal SC, OT & UV protection.
Fault output of OT protection operate by lower arm
Fault output of OT, UV protection given pulse while over level.
VN1-VNC
VP1-VPC
Trip level
Reset level
Trip level
Reset level
(Note-2)
(Note-2)
Min.
—
—
1.2
1.7
500
—
111
—
11.5
—
—
—
1.0
4.5
Limits
Typ.
2.35
2.55
2.20
0.8
0.2
0.3
1.8
0.6
—
—
Limits
Typ.
27
27
1.5
2.0
—
10
118
100
12.0
12.5
—
10
1.8
5.1
Unit
Max.
2.80
3.05
V
3.30
V
2.1
0.3
1.1
µs
2.9
1.2
1
10
mA
Max. Unit
38
mA
38
1.8
V
2.3
—
A
—
µs
125
°C
—
12.5
V
—
0.01
mA
15
—
ms
5.6
V
Jun. 2005