MITSUBISHI INTELLIGENT POWER MODULES
PM100CSA120
FLAT-BASE TYPE
INSULATED PACKAGE
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Control Sector
Over Current Trip Level Inverter Part
Short Circuit Trip Level Inverter Part
Over Current Delay Time
Over Temperature Protection
Supply Circuit Under Voltage Protection
Supply Voltage
Circuit Current
Input ON Threshold Voltage
Input OFF Threshold Voltage
PWM Input Frequency
Fault Output Current
Minimum Fault Output Pulse Width
OC
SC
toff(OC)
OT
OTr
UV
UVr
VD
ID
Vth(on)
Vth(off)
fPWM
IFO(H)
IFO(L)
tFO
-20°C ≤ T ≤ 125°C, VD = 15V
145
-20°C ≤ T ≤ 125°C, VD = 15V
—
VD = 15V
—
Trip Level
111
Reset Level
—
Trip Level
11.5
Reset Level
—
Applied between VUP1-VUPC,
VVP1-VVPC, VWP1-VWPC, VN1-VNC
VD = 15V, VCIN = 15V, VN1-VNC
VD = 15V, VCIN = 15V, VXP1-VXPC
Applied between
13.5
—
—
1.2
UP-VUPC, VP-VVPC, WP-VWPC,
1.7
UN · VN · WN-VNC
3-φ Sinusoidal
—
VD = 15V, VFO = 15V
—
VD = 15V, VFO = 15V
—
VD = 15V
1.0
Typ. Max. Units
230
— Amperes
340
— Amperes
10
—
µs
118
125
°C
100
—
°C
12.0 12.5 Volts
12.5
—
Volts
15
16.5 Volts
40
55
mA
13
18
mA
1.5
1.8
mA
2.0
2.3
mA
15
20
kHz
—
0.01
mA
10
15
mA
1.8
—
ms
Sep.1998