Operational Specifications
Description
Nominal
Range
Power
300 watts
175-305 watts
Current
22 amps (DC)
13-23 amps (DC)
Operating Voltage
13.5 volts (DC)
11.5-15 volts (DC)
Ignition Voltage
23 kilovolts (recommended minimum)
Temperature
150º C (maximum)
Lifetime*
1000 hours (500 hour warranty)
* End of lamp life is defined as 50% of initial output.
Output at Nominal Power
F= UV Filtered Output/ UV = UV Enhanced Output
Description
PE300B-10F
PE300B-10UV
Radiant Output*
UV Output*
IR Output*
Visible Output*
Color Temperature
Peak Instabilities
65 watts
3.3 watts
32 watts
6500 Lumens
5900 Kelvin
4%
65 watts
8.5 watts
30 watts
5850 Lumens
5050 Kelvin
4%
Spot Size at Crossover .09” at 50% pts
0.9” at 50% pts
Spot Size at Crossover .23” at 10% pts
.23” at 10% pts
*These values indicate total output in all directions.
Wavelengths = UV<390nm, IR>770nm, Visible 390nm to 770nm.
** Beam Geometry defined as half angle at 10% PTS after 01/100/1000 hours.
Dimensions
.165
(4.19)
1.00
(25.4)
.250 (6.35)
.55 (13.97)
.250 (6.35)
1.00
(25.4)
Physical Specifications
Description
Arc Gap
Reflector Geometry
Weight
Window Diameter
Specification
.038 inch (0.96mm)
Ellipsoidal 1= X2/M2 +Y2/N2
150 grams
1 inch (25.4 mm)
Focused Output
Description
Visible Output*
6mm aperture
3500 Lumens
3mm aperture
2000 Lumens
* Nominal values at 300 watts after 2 hour burn-in
Total Output
32 watts
20 watts
Notes
1. Lamp must not be operated with window facing upwards within
45º of vertical.
2. Seal temperature must not exceed 150º C.
3. Current/power regulated power supplies and PerkinElmer lamp
housing units are recommended.
4. Lamp must be operated within recommended current and power
range. Over powering may lead to arc instability, hard starting
and premature aging.
5. Hot mirror assembly is available for IR filtering.
6. CERMAX lamps are much safer lamps to use than their quartz
xenon arc lamp equivalents. However, caution must be practiced
when operating lamps because they are under high pressure,
require high voltage, reach temperatures up to 200º C, and their
IR and UV radiation can cause skin burns and eye damage.
Read hazard sheet included with each lamp shipment.
Spectral Output
F
UV
F + HOT MIRROR
100
80
6-32 UNC 2B x .156 DP 2 x .40 (10.2)
3 Holes EQ SP on A
.750 (19.05) BC
.035 (.899)
1.298
2.167 (55.04)
(32.97)
60
.866 (21.99)
M=1.059
.008 (.203)
N=0.50
40
.126 (3.2)
20
Focal Point
Cathode
Reflector Edge
CL Ellipse
Dimensions in parentheses are in millimeters.
0
200
300 400 500
600 700
800
900 1000 1100
WAVELENGTH (NM)
PerkinElmer welcomes inquiries about special lamps. We would be pleased to discuss the requirements of your application and the feasibility of
designing a lamp specifically suited to your needs.
For more information e-mail us at opto@perkinelmer.com or visit our web site at www.perkinelmer.com/opto.
All values are nominal; specifications subject to change without notice.
USA:
Europe:
Asia:
PerkinElmer Optoelectronics
PerkinElmer Optoelectronics GmbH PerkinElmer Optoelectronics
44370 Christy St.
Wenzel-Jaksch-Str. 31
47 Ayer Rajah Crescent #06-12
Fremont, CA 94538
65199 Wiesbaden
Singapore 139947
Phone: (510) 979-6500
Germany
Phone: +65 775 2022
Fax: (510) 687-1140
Toll Free: (800) 775-6786
Phone: +49 611 492 0
Fax: +49 611 492 369
Fax: +65 775 1008
.
© 2000 PerkinElmer inc. All rights reserved.
www.perkinelmer.com/opto
DS-166 Rev C 1101

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]