datasheetbank_Logo
データシート検索エンジンとフリーデータシート

VSK-S10-9UA データシートの表示(PDF) - CUI INC

部品番号
コンポーネント説明
一致するリスト
VSK-S10-9UA
CUI
CUI INC CUI
VSK-S10-9UA Datasheet PDF : 4 Pages
1 2 3 4
For more information, please visit the product page.
CUI Inc SERIES: VSK-S10 DESCRIPTION: AC-DC POWER SUPPLY
date 08/27/2012 page 2 of 4
INPUT
parameter
voltage
frequency
current
inrush current
external input fuse
(recommended)
conditions/description
at 110 Vac
at 230 Vac
at 110 Vac
at 230 Vac
slow blow, 250 V
min
typ
max
units
85
264
Vac
120
370
Vdc
47
63
Hz
230
mA
120
mA
10
A
20
A
2
A
OUTPUT
parameter
line regulation
load regulation
temperature coefcient
hold-up time
switching frequency
conditions/description
10 ~ 100%
at 230 Vac
min
typ
±0.5
±1
0.02
50
60
max
units
%
%
%/°C
ms
kHz
PROTECTIONS
parameter
over current protection
short circuit protection
conditions/description
min
typ
max
units
110
%
auto recovery with no damage from a short on any output
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
isolation voltage
primary to secondary (for 1 minute)
4,000
Vac
safety approvals
IEC 60950-1, EN 60950-1, UL 60950-1
safety class
class II
EMI/EMC1
EN 55011 (level B), IEC/EN 61000-4-2 level 4 (8kV/15kV), IEC/EN 61000-4-3, IEC/EN 61000-4-4 level
4 (4kV), IEC/EN 61000-4-5 level 4 (2kV/4kV)
leakage current
230 V ac, 50 Hz
0.1
mA
RoHS compliant
yes
MTBF
25°C
300,000
hrs
ENVIRONMENTAL
parameter
conditions/description
operating temperature
storage temperature
case temperature
operating humidity
non-condensing
Notes: 1. external EMC application circuit is required
min
typ
max
units
-25
70
°C
-40
105
°C
95
°C
95
%
cui.com