TC74AC574P/F/FT
AC Characteristics (CL = 50 pF, RL = 500 Ω, input: tr = tf = 3 ns)
Characteristics
Propagation delay
time
(CK-Q)
Output enable time
Output disable time
Maximum clock
frequency
Input capacitance
Output capacitance
Power dissipation
capacitance
Symbol
tpLH
tpHL
tpZL
tpZH
tpLZ
tpHZ
fmax
CIN
COUT
CPD
Test Condition
VCC (V)
3.3 ± 0.3
―
5.0 ± 0.5
Ta = 25°C
Min Typ. Max
―
9.8 16.7
―
6.1 9.2
―
―
―
―
―
3.3 ± 0.3 ―
5.0 ± 0.5 ―
3.3 ± 0.3 ―
5.0 ± 0.5 ―
3.3 ± 0.3 50
5.0 ± 0.5 95
―
―
9.2 15.8
6.1 9.3
6.6 11.0
5.8 8.8
100
―
160
―
5
10
10
―
(Note) ―
36
―
Ta =
−40 to 85°C Unit
Min Max
1.0 19.0
ns
1.0 10.5
1.0 18.0
ns
1.0 10.6
1.0 12.5
ns
1.0 10.0
50
―
MHz
95
―
―
10
pF
―
―
pF
―
―
pF
Note:
CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
ICC (opr) = CPD·VCC·fIN + ICC/8 (per F/F)
And the total CPD when n pcs. of latch operate can be gained by the following equation:
CPD (total) = 26 + 10·n
5